CP-220 DEDICATED ENGLISH FOR SILENT KNIGHT FSK 2 PREMISES CODES
PREMISES
CODE
CP-220 ENGLISH LANGUAGE
COMMENTS
F3xy
SUPERVISED CLOSING xy
Control panels programmed for supervised closing require
that the system be armed at a specified time by an
authorized user; if it's not, it will report a
SUPERVISED
closing and the number of the individual (xy) who ultimately
arms (and closes) the system.
F7xy
SUPERVISED OPENING xy
Control panels programmed for supervised opening require
that the system be disarmed at a specified time by an
authorized user; if it's not, it will report a
SUPERVISED
opening and the number of the individual (xy) who ultimately
disarms (and opens) the system.
FD0a
CLOSING
AREA
0a
Reports the closing of designated groups of zones
(designated by
a) within the same system; such areas must
not be confused with separate partitions (each of which
would report to the Central Station via a unique account
number). This report is preceded by an applicable closing
event (as described in one of the previous four categories)
identifying a user, if relevant.
FF0a
OPENING
AREA
0a
Reports the opening of designated groups of zones
(designated by
a) within the same system. Such areas must
not be confused with separate partitions (each of which
would report to the Central Station via a unique account
number). This report is preceded by an applicable opening
event (as described in one of the previous four categories)
identifying a user, if relevant.
F8xy
ACCESS GRANTED ID xy
Identifies the user, designated by
xy, whose was granted
entrance through one of the system's designated
access-controlled doors.
F9xy
ACCESS LEFT OPEN ID xy
Is reported when an access-controlled door is left open too
long, identifying the user, designated by
xy, who last
operated the door and is likely responsible for leaving the
door open for too long.
FAcc
ACCESS (FORCED) STATION ID
cc
Indicates, via the keystation number designated by
cc, which
access-controlled door was forced open and caused an
alarm.
FC00
DURESS
A silent holdup alarm that
does not report the user number of
the individual initiating the alarm.
CP-220A Central Station Receiver Appendix B:
Page B-37
Hook-Up and Installation Manual
Communication Formats