REPORTING CODE
REPORTING CODE
1st CHARACTER
2nd CHARACTER
1st CHARACTER
2nd CHARACTER
1 FIRE
1-9 ZONES
8 ZONE 1-9 ZONES
1-9
TROUBLE
1-9
2 HOLDUP
1-9
ZONES
9
TEST
0
DOESN'T
(SILENT)
1-9
APPLY
3
BURG
1-9
ZONES
B OPENING 0-F USERS
0-F
1-9
(PREMISES)
4 MEDICAL
1-9
ZONES
C CLOSING 0-F USERS
0-F
EMER
1-9
(PREMISES)
5
PANIC
1-9
ZONES
D
ABORT
0
DOESN'T
(AUDIBLE)
1-9
SIGNAL
APPLY
6 ZONE 1-9 ZONES
E ZONE 1-9 ZONES
BYPASS
1-9
RESTORE
1-9
7 ENVIRON
1-9
ZONES
F
SYSTEM
0-F
EVENTS
EMER
1-9
TROUBLE
0-F
TABLE 1-1
EXAMPLES:
FULL
MESSAGE
CUSTOMER
ACCT NO.
REPORTING
CODE
MEANING
1234 32
1234
32
a BURGLAR ALARM has occurred due to the violation of
an alarm sensor on Zone 2
2412 81
2412
81
a TROUBLE (e.g., a wiring fault) has been detected on
Zone 1, which may compromise its integrity
1867 9
1867
9
a TEST REPORT has been initiated at the protected
premises
1234 E2
1234
E2
a previously reported violation of Zone 2 has been
restored to normal
4657 69
4657
69
the security system was armed with its Zone 9 bypassed
769 C
769
C
an employee of Customer Account 7609, assigned to
USER CODE, has closed the premises by arming the
system
2232 F1
2232
F1
a SYSTEM TROUBLE (e.g., a loss of AC Power or a Low
Battery) has occurred in the security equipment
6574 D
6574
D
an ALARM, likely to be caused in error, was cancelled by
the user shortly after it was initiated
769 B1
769
B1
an employee of Customer Account 7609, assigned to
USER CODE 1, has opened the premises by disarming
the system
NOTE: The characters "B" through "F" are used to increase the number of variations capable of being
reported by most communication formats, when compared to those using only the digits between "0" and "9."
Using such "alpha" characters in designating numbers is characteristic of a numbering system known as
hexadecimal,
which is often used in computers and discussed in
Appendix A
. Note, too, that for technical
reasons, hexadecimal "A" is not used in many alarm communication formats. See
Appendix B
for additional
information.
Page 1-4
Section 1: Getting Acquainted CP-220A Central Station Receiver
Hook-Up
and
Installation
Manual