4-51
Intelligent output terminal setting
Any of the following functions can be assigned to the intelligent
Output terminals (11 or 12) or the alarm relay.
Both intelligent output terminals 11 and 12 and the alarm relay
are all relay outputs.
All three output relays can be selected to be either NO or NC (a or b).
Data
Description
Reference item
Page
00
RUN:Signal during run
Signal during run
4-53
01
FA1:Frequency arrival signal at the time of
constant speed
02
FA2:Frequency arrival signal at the time of
over setting frequency
Frequency arrival signal
4-53
03
OL:Overload advance notice signal
Overload advance notice signal
4-38
04
OD:output deviation for PID control
PID function
4-30
05
AL:Alarm signal
Protection function
-
06
FA3:Arrival signal for only setting frequency Frequency arrival signal
4-53
08
IP:Instantaneous stop signal
09
UV:Under voltage signal
Instantaneous stop/under-voltage
4-34
11
RNT:RUN time over
RUN time over
4-55
12
ONT:ON time over
Power ON time over
4-55
13
THM:Thermal caution
Electric thermal function
4-38
Chapter 4 Explanation of function
C021-C022 : Intelligent output terminal
C026 : Alarm relay output terminal setting
Relation code