4-33
Acceleration and deceleration pattern
(1) Selection of pattern
Pattern of acceleration and deceleration speed is possible to set up
corresponding to each system.
Select the pattern of acceleration and deceleration with A097 and A098.
Set
value
00
01
02
03
Curve
Line
Sigmoid
U-shape
Reverse U-shape
A097
( Accel-
eration)
A098
(Decel-
eration)
Contents
Accelerate and
decelerate in line
until output
frequency set value.
Collapsing the cargo
such as the going up
and down machine,
conveyor it uses it for
prevention.
Cutting the tension control, rolled book such
as the volume collector machine it uses it for
prevention.
It is possible to set the pattern of both acceleration, deceleration.
(2) The curve constant (the swelling degree)
It makes the rough sketch reference and please decide the swelling degree.
There is the range which the midway adjustable-speed time becomes fast in the S character pattern.
Tim e
Output f requency
Output f requency
Tim e
Tim e
Output f requency
Tim e
Output f requency
Tim e
Output f requency (Hz)
Goal
frequency
(100%)
96.9
82.4
17.6
3.1
Acceleration tim e to
output frequency set
v alue
(100%)
25
50
75
10
02
10
02
Tim e
Output f requency (Hz)
Goal
frequency
(100%)
99.6
93.8
35
Acceleration tim e to
output frequency
set v alue (100%)
25
50
75
10
10
02
87.5
68.4
64.6
Tim e
Output f requency (Hz)
Goal
frequency
(100%)
65
35.4
0.39
Acceleration tim e
to output f requency
set v alue (100%)
25
50
75
10
02
31.6
12.5
6.25
Tim e
Output f requency
Tim e
Output f requency
Tim e
Output f requency
Tim e
Output f requency
Chapter4 Explanation of function
A097: Acceleration pattern selection
A098: Deceleration pattern selection
A131: Acceleration curve constant
A132: Deceleration curve constant
Relation code