4-42
Intelligent input terminal setting
It is possible to operate functions by assigning those functions to the
intelligent input terminals 1-5 (C001-C005).
The intelligent input terminals 1-5 can be selected individually whether the contact input specification is either
a NO or a NC contact.
Two or more intelligent input terminals can’t be assigned to be the same function.
If an intelligent input is assigned a function which is already assigned to another terminal it will automatically
be restored back to the setting before.
Function Code
Data
Description
Reference item
Page
01
RV:Reverse command
Operation run
4-14
02
CF1:Multi-speed 1 (binary operation)
03
CF2:Multi-speed 2 (binary operation
04
CF3:Multi-speed 3 (binary operation)
05
CF4:Multi-speed 4 (binary operation)
Multi-speed operation function
4-43
06
JG:Jogging
Jogging operation
4-44
07
DB:External DC braking
DC braking(external DC braking)
4-26
08
SET:2
nd
Set of Motor Data
2
nd
Set of Motor Data
4-45
09
2CH:Two-stage adjustable-speed
Two-stage adjustable-speed function 4-32
11
FRS:Free-run stop
Free-run stop
4-46
12
EXT:External trip
External trip
4-50
13
USP:Unattended start protection
Unattended start protection function
4-49
14
CS:Commercial change
Commercial change
4-47
15
SFT:Software lock (control terminal)
Software lock
4-45
16
AT:analog input voltage/current select
Analog external input
4-19
18
RS:Reset inverter
Reset inverter
4-48
20
STA:3 wire start
21
STP:3 wire stop
22
F/R:3 wire direction
3 wire input function
4-50
23
PID:PID selection (valid/invalid)
24
PIDC:PID integrating reset
PID function
4-30
27
UP:Remote control UP function
28
DWN:Remote control DOWN function
29
UDC:Remote control data clear
UP/DOWN function
4-49
31
OPE:force operation ope
force operation ope function
4-55
32
SF1:Multi-speed 1 (bit run)
33
SF2:Multi-speed 2 (bit run)
34
SF3:Multi-speed 3 (bit run)
35
SF4:Multi-speed 4 (bit run)
36
SF5:Multi-speed 5 (bit run)
37
SF6:Multi-speed 6 (bit run)
38
SF7:Multi-speed 7 (bit run)
Multi-speed operation function
4-43
39
OLR:Overload restriction change
Overload restriction
4-38
C001- C005
no
NO:No assign
-
-
Input terminal a/b (NO/NC) selection
It is possible to set a contact input or b contact input to
intelligent input terminals 1-5 and FW terminals individually.
Set item
Function code
Data
Description
00
A contact(NO)
Intelligent input 1-5
a/b(NO/NC)selection
C011-C015
01
B contact(NC)
00
A contact(NO)
Input FW
a/b(NO/NC)selection
C019
01
B contact(NC)
C001-C005: Intelligent input terminal
Relation code
C011-C015: Intelligent input a/b (NO/NC)
selection
C019 :Input FW a/b (NO/NC) selection
Relation code
a contact: “ON” with Close, “OFF” with Open
b contact: “ON” with Open, “OFF” with Close
RS terminal can set only a contact.
Chapter 4 Explanation of function