4-6
Function Mode
Code
Function name
Setting range
Initial data
-FE/-FU/-FR
Setting
on run
Change
mode on
run
Page
A001
Frequency setting selection
00(VR)/01(terminal)/02(operator)/03(RS485)/
04(option1)/05(option2)
01/01/00
4-14
A002
Operation setting selection
01(terminal)/02(operator)/03(RS485)/04(option1)/05(option2)
01/01/02
4-15
A003
Base frequency
30. - Maxi mum. frequency(Hz)
50./60./60.
4-17
A203
Base frequency, 2nd motor
30. - 2
n d
Maxi mum. frequency (Hz)
50./60./60.
4-17
A004
Maxi mum frequency
30. - 400. (Hz)
50./60./60.
4-18
A204
Maxi mum frequency, 2nd
motor
30. - 400. (Hz)
50./60./60.
4-18
A005
AT terminal selection
00( Changing of O and OI with AT terminal)/01(Changing of O and O2
with AT terminal)
00
4-19
A006
02 selection
00(single)/01(auxiliary speed of O, OI) [no reversible]
/02(auxiliary speed of O, OI [reversible]
00
4-19
A011
0 start
0.00-99.99/100.0-400.0 (Hz)
0.00
9
4-20
A012
0 end
0.00-99.99/100.0-400.0 (Hz)
0.00
9
4-20
A013
0 start rate
0.-100.0 (%)
0.
9
4-20
A014
0 end rate
0.-100.0(%)
100.
9
4-20
A015
0 start selection
00 (external starting frequency)/01(0Hz)
01
9
4-20
A016
O, OI, O2 sampling
1.-30.(ti mes)
8.
9
4-21
A019
Multi-speed selection
00(binary : range is to 16 stage speed with 4 terminals)/01(bit : range
is to 6 stage speed with 5 terminals)
00
4-43
A020
Multi-speed 0
0.00, starting frequency-maxi mum. frequency(Hz)
0.00
9
9
4-43
A220
Multi-speed 0, 2
n d
motor
0.00, starting frequency-2
n d
maxi mum frequency(Hz)
0.00
9
9
4-43
A021
Multi-speed1
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A022
Multi-speed2
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A023
Multi-speed3
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A024
Multi-speed4
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A025
Multi-speed5
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A026
Multi-speed6
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A027
Multi-speed7
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A028
Multi-speed8
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A029
Multi-speed9
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A030
Multi-speed10
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A031
Multi-speed11
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A032
Multi-speed12
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A033
Multi-speed13
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A034
Multi-speed14
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A035
Multi-speed15
0.00, starting frequency-maxi mum frequency(Hz)
0.00
9
9
4-43
A038
Jogging frequency
0.00, starting frequency-9.99(Hz)
1.00
9
9
4-44
A039
Jogging selection
00(free-run on JG stop / invalid on running) / 01(stop decelerating on
JG stop / invalid on running) / 02(DC braking on JG stop/invalid on
running) / 03(free-run on JG stop/valid on running[JG after stop
decelerating]) / 04 (stop decelerating on JG stop/valid on running) /
05 (DC braking on JG stop/valid on operating)
00
9
4-44
A041
Torque boost selection
00 (manual torque boost) / 01 (automatic torque boost)
00
4-24
A241
Torque boost selection, 2
n d
motor
00 (manual torque boost) / 01 (automatic torque boost)
00
4-24
A042
Manual torque boost
0.0-20.0(%)
1.0
9
9
4-24
A242
Manual torque boost, 2
n d
motor
0.0-20.0(%)
1.0
9
9
4-24
A043
Manual torque boost point
0.0-50.0(%)
5.0
9
9
4-24
A243
Manual torque boost point, 2
n d
motor
0.0-50.0(%)
5.0
9
9
4-24
A044
1
s t
control
00/(VC)/01(VP1.7power)/02(free V/f setting)
00
4-22
A244
2
n d
control
00/(VC)/01(VP1.7power)/02(free V/f setting)
00
4-22
A045
Output voltage gain
20. - 100. (%)
100.
9
9
4-21
A051
DC braking selection
00(invalid)/01(valid)
00
9
4-25
A052
DC braking frequency
0.00-60.00(Hz)
0.50
9
4-25
A053
DC braking wait time
0.0 - 5.0(s)
0.0
9
4-25
A054
DC braking power
0. - 70. (%)
0.
9
4-25
A055
DC braking ti me
0.0 - 60.0(s)
0.0
9
4-25
A056
DC braking edge/level
selection
00(edge action)/01(level action)
01
9
4-25
A057
DC braking power
(starting time)
0. - 70. (%)
0.
9
4-25
A058
DC braking ti me
(starting time)
0.00-60.0(s)
0.0
9
4-25
A059
DC carrier frequency
0.5-12(kHz) Derating <0.5-8(kHz)>
3.0
4-25
Chapter 4 Explanation of function
B
a
se s
e
tt
in
g
M
u
lt
is
tag
e
spe
e
d
• j
o
ggi
ng f
requ
e
ncy se
tt
in
g
V
/f ch
arac
ter
ist
ic
D
ir
e
ct cu
rre
nt br
ak
in
g
A
n
al
og
i
n
pu
t
s
e
tt
in
g
(Note)<>indicate the setting range of 90 to 132kW