8. Troubleshooting
257
SMGB0079 rev.0 - 01/2013
8
Expansion opening indication
28 Indoor unit expansion valve
opening (%)
L1
20
29 Outdoor unit expansion valve
MV1 opening (%)
L2
gg
30 Outdoor unit expansion valve
MV2 opening (%)
L3
gg
In case of models without the expansion valve (MV2), the
same figure is displayed
31 Control information
L4
00
Estimated electric current indication
32 Compressor running current (A)
P1
25
The total current is displayed when several compressors are
running.
In case of the inverter compressor, the running current of the
primary side of the inverter is displayed.
Returns to
temperature indication