background image

For the user

V 12-025 W
V 12-035 W
V 12-050 W
V 12-060 W
V 12-060 M2W

User Manual

Air Conditioner - climaVAIR

Split Wall-Mounted type

EN

Summary of Contents for V 12-025 W

Page 1: ...For the user V 12 025 W V 12 035 W V 12 050 W V 12 060 W V 12 060 M2W User Manual Air Conditioner climaVAIR Split Wall Mounted type EN...

Page 2: ...e COOL 8 7 5 3 Dehumidifying Mode DRY 8 7 5 4 Heating Mode HEAT 9 7 6 Defrosting 9 7 7 Setting the Direction of the Airflow 9 7 7 1 Horizontal Airflow 9 7 7 2 Vertical Airflow 9 7 8 TURBO 10 7 9 Speci...

Page 3: ...Note The information relating to this unit is divided between two manuals installation manual and user manual Note The appliance is not intended for use by young children or infirm persons without sup...

Page 4: ...egard to obtaining the CE Marking 5 Description of the Unit This unit is comprised of the following elements Indoor unit Outdoor unit Remote controller Interconnecting services Supplied accessories Fi...

Page 5: ...d weather Anti freeze All heat pump units will tend to freeze up during the colder winter months the anti freeze function automatically defrosts the outdoor coil as required Anti corrosion casing Outd...

Page 6: ...nt whilst using insecticides or pesticides These could settle in the unit and harm the health of persons with allergies to specific chemical substances Avoid prolonged direct exposure to cooled air or...

Page 7: ...n FAN SPEED 6 SLEEP button NIGHT TIME FUNCTION 7 TIMER button START UP TIME 8 TURBO button MAXIMUM FAN SPEED 9 ION button function not available 10 LIGHT button 11 LOCK button 7 2 2 Display Indicators...

Page 8: ...the LOCK mode press this button again 7 5 Selection of the Operation Mode Press the ON OFF button on the remote controller pointing at the unit press the MODE button to select the needed mode auto co...

Page 9: ...d by fast defrosting and it does not mean a performance failure Once the unit completes the defrosting process it resumes the heating operation 7 7 Setting the Direction of the Airflow The direction o...

Page 10: ...the day the cooling heating capacity will be reduced since the room temperature is too high COOL mode The unit is operational for a maximum of 24 hours in SLEEP mode In COOL mode The ambient temperatu...

Page 11: ...nect automatically Note The automatic connection can only be made with the unit switched off Press the OFF button Press the TIMER button The timer settings range from 1 to 24 hours Each time the TIMER...

Page 12: ...a i e the walls doors windows ceiling and floor the adjacent rooms are cooler than the room temperature therefore thermal energy is unintentionally lost It is therefore difficult to adequately heat th...

Page 13: ...es can be caused by the refrigerant circulating inside the unit during operation Cracking noises can be caused by heat expansion or contraction of plastics when the unit is stopped Consult after sales...

Page 14: ...new If strong odours continue to be a problem contact your after sales service provider to fully deep clean the unit Warning Do not use hot water to clean the filters Warning Do not leave the filters...

Page 15: ...rant leakage short circuiting or even fire could be caused 12 Product Decommissioning Danger of injury and physical damage When disposing of the product ensure that is done safely and in accordance wi...

Page 16: ...ant reserves the right to make modifications without prior warning Vaillant Ltd Vaillant House Medway City Estate Trident Close Rochester Kent ME2 4EZ Telephone 0164 292300 Fax 0164 290166 www vaillan...

Reviews: