background image

Air Conditioning
Technical Data

FHQ-CB

> FHQ35CBVEB
> FHQ50CBVEB
> FHQ60CBVEB
> FHQ71CBVEB
> FHQ100CBVEB
> FHQ125CBVEB

> FHQ140CBVEB

Summary of Contents for FHQ-CB

Page 1: ...Air Conditioning Technical Data FHQ CB FHQ35CBVEB FHQ50CBVEB FHQ60CBVEB FHQ71CBVEB FHQ100CBVEB FHQ125CBVEB FHQ140CBVEB ...

Page 2: ......

Page 3: ... Features 2 2 Specifications 3 Technical Specifications 3 Electrical Specifications 3 3 Options 4 4 Dimensional drawings 5 5 Piping diagrams 8 6 Wiring diagrams 9 Wiring Diagrams Single Phase 9 7 External connection diagrams 10 8 Sound data 11 Sound Pressure Spectrum 11 ...

Page 4: ...ylish unit blends easily with any interior The flaps close entirely when the unit is not operating and there are no air intake grilles visible No optional adapter needed for DIII connection link your unit into the wider building management system Drain pump kit available as accessory Fresh air intake integrated in the same system thus reducing installation cost as no additional ventilation device ...

Page 5: ...m min 10 11 5 14 20 23 24 cfm 353 406 494 706 812 848 Nom cfm 406 424 530 600 848 953 1 024 m min 11 5 12 15 17 24 27 29 Fan motor Quantity 1 Model KFD 280 87 8A KFD 280 117 8A EQDW01EDK Speed Steps 3 Output High W 60 91 150 Phase x Voltage V DC280V DC192V 380V Full load amps FLA Cooling A 0 6 0 8 1 2 1 6 1 8 Heating A 0 6 0 8 1 2 1 6 1 8 Sound power level Cooling dBA 53 54 55 60 62 64 Heating dBA...

Page 6: ...ŽƐƐŝďůĞ ŝŶ ĐŽŵďŝŶĂƚŝŽŶ ǁŝƚŚ ƐŝŵƉůŝĨŝĞĚ ƌĞŵŽƚĞ ĐŽŶƚƌŽů Z Ϯ ϯ ϱϮ ϳ ůĞĐƚƌŝĐĂů ďŽdž ǁŝƚŚ ĞĂƌƚŚ ƚĞƌŵŝŶĂů Ϯ ďůŽĐŬƐͿ ϮϭϮ ŝŐŝƚĂů ŝŶƉƵƚ ĂĚĂƉƚŽƌ ZWϳ ϱϮ ϲͿ ϳͿ ZĞŵŽƚĞ ƐĞŶƐŽƌ Z ϬϭͲϰ ZĞŵŽƚĞ ΗKE K Η ĂŶĚ ΗĨŽƌĐĞĚ K Η Ŭŝƚ ZKZϬϰ ůĞĐƚƌŝĐĂů ďŽdž ǁŝƚŚ ĞĂƌƚŚ ƚĞƌŵŝŶĂů ϯ ďůŽĐŬƐͿ ϯϭϭ tŝƌŝŶŐ ĂĚĂƉƚŽƌ ĨŽƌ ĞůĞĐƚƌŝĐĂů ĂƉƉĞŶĚŝĐĞƐ ZWϰ ϱϮ ϲͿ ŶƐƚĂůůĂƚŝŽŶ ďŽdž ĨŽƌ ĂĚĂƉƚŽƌ W ZWϭ ϵϯ DŽƵŶƚŝŶŐ ƉůĂƚĞ ĨŽƌ ĂĚĂƉƚŽƌ W ŝŶƐƚĂůůĂƚŝŽŶ ďŽdž WϱϬ ϱϲ Ͳ ...

Page 7: ...3 4 Split Sky Air FHQ CB 5 Indoor Unit FHQ CB 4 Dimensional drawings 4 1 Dimensional Drawings ...

Page 8: ... Indoor Unit FHQ CB 4 Split Sky Air FHQ CB 6 4 Dimensional drawings 4 1 Dimensional Drawings ...

Page 9: ...3 4 Split Sky Air FHQ CB 7 Indoor Unit FHQ CB 4 Dimensional drawings 4 1 Dimensional Drawings 3D069633D ...

Page 10: ... Indoor Unit FHQ CB 5 Split Sky Air FHQ CB 8 5 Piping diagrams 5 1 Piping Diagrams QGRRU XQLW LHOG SLSLQJ LHOG SLSLQJ 㻌㻭㻌㻌㻌㻌㻯㻝㻞㻞㻜㼀㻙㻜 㻌㻮㻌㻌㻌㻌㻯㻝㻞㻞㻜㼀㻙㻜 7R RXWGRRU XQLW FHQ CB 3D101475 ...

Page 11: ...3 6 Split Sky Air FHQ CB 9 Indoor Unit FHQ CB 6 Wiring diagrams 6 1 Wiring Diagrams Single Phase ...

Page 12: ... Indoor Unit FHQ CB 7 Split Sky Air FHQ CB 10 7 External connection diagrams 7 1 External Connection Diagrams ...

Page 13: ...3 8 Split Sky Air FHQ CB 11 Indoor Unit FHQ CB 8 Sound data 8 1 Sound Pressure Spectrum ...

Page 14: ... Indoor Unit FHQ CB 8 Split Sky Air FHQ CB 12 8 Sound data 8 1 Sound Pressure Spectrum 4D069652D 4D069650F 4D069651F ...

Page 15: ... is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N V Daikin Europe N V has compiled the content of this leaflet to the best of its knowledge No express or implied warranty is given for the completeness accuracy reliability or fit ness for particular purpose of its content and the products and services presented therein Specifica tions are subject ...