10.4.1.16 Removing other electrical components
1
Remove the service cover following
Removing service cover
in this chapter.
2
Open the P plate turning counter clockwise approximately 90° following
Opening electrical box (P plate)
.
• Check that the LED201 (red) on Inverter is OFF when the P plate is opened.
D A N G E R
DO NOT touch electrical components while the LED201 (Red) is ON to avoid electrical shock. Wait until the
LED turns off.
CMC
1
Remove all the wiring connected to CMC.
2
Remove 2 screws fixing the CMC.
Reactor
1
Remove 4 screws fixing the reactor.
Noise filter
1
Remove all the wiring connected to the noise filter.
2
Hold the upper part of the 6 holders with the long nose pliers
and remove the noise filter.
Holder
Long-Nose Pliers
Noise Filter
Holder
Noise filter
Long nose pliers
Fuse
Noise filter
Reactor
CMC
Holders
Screws
Holders
Screws
N O T E
• To connect wiring at reassembling, ensure that the terminal numbers and wiring mark band codes are mat-
ched. If connections are wrong, there is the possibility of wrong operation and to cause damage to electrical
parts.
• When attaching the PCB, or when attaching the parts attached to the PCB, pay attention not to clamp any wi-
ring between plates or electrical components.
Summary of Contents for EV-1.5N1
Page 2: ......
Page 4: ... II ...
Page 26: ......
Page 100: ......
Page 144: ...5 Control System 130 SMGB0079 rev 0 01 2013 5 4 2 Dry operation Continues in the next page ...
Page 148: ...5 Control System 134 SMGB0079 rev 0 01 2013 5 4 4 Automatic cooling and heating operation ...
Page 158: ......
Page 196: ......
Page 212: ...8 Troubleshooting 198 SMGB0079 rev 0 01 2013 ...
Page 215: ...8 Troubleshooting 201 SMGB0079 rev 0 01 2013 8 ...
Page 323: ...9 Spare parts 309 SMGB0079 rev 0 01 2013 9 RAS 8 10 HNCE Spare Parts Document EPN 201211B ...
Page 332: ......
Page 452: ......
Page 479: ......