4.20 Siderail Control Cable
Chapter 4: Removal, Replacement, and Adjustment Procedures
Basic Care™ Bed Service Manual (man336)
Page 4 - 49
4
CAUTION:
Use caution when cutting wire ties. Failure to do so could result in cable
damage.
12. Carefully cut all of the wires ties attaching the siderail cable (I) to the bed
frame (M).
13. Disconnect the siderail cable (I) from the control box assembly (B).
Replacement
CAUTION:
Keep enough slack in the cables to allow the bed to move through its
full range of motion without putting force on any of the cables. Failure to
do so could result in equipment damage.
1. When routing the siderail cable (I), make sure it has enough slack for the
bed to move through its full range of motion.
2. Route the siderail cable (I) from the control box assembly (B) to the
siderail (A).
NOTE:
The connector will not fit through the bracket.
3. Do the removal procedure in the reverse order.