Testing and running | Program run
6
Interrupting, stopping or aborting machining
There are several ways to stop a program run:
Interrupt the program run with e.g. the miscellaneous function
M0
Interrupt the program run e.g. with the
NC stop
soft key
Stop the program run (e.g., with the
NC stop
key in combination
with the
INTERNAL STOP
soft key)
Terminate the program run e.g. with the miscellaneous functions
M2
or
M30
The control shows the current status of the program run in the
status display.
"General status display", Page 68
In contrast to a stopped run, an interrupted, aborted (terminated)
program run enables certain actions by the user, including the
following:
Select operating mode
Check Q parameters and change these if necessary using the
Q INFO
function
Change setting for the optional programmed interruption with
M1
Change setting for the programmed skipping of NC blocks with
/
During major errors, the control automatically aborts
the program run (e.g., during a cycle call with stationary
spindle).
274
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022
Summary of Contents for TNC 620
Page 4: ...Contents 4 HEIDENHAIN TNC 620 User s Manual for Setup Testing and Running NC Programs 01 2022...
Page 6: ...Contents 6 HEIDENHAIN TNC 620 User s Manual for Setup Testing and Running NC Programs 01 2022...
Page 24: ......
Page 25: ...1 Basic information...
Page 43: ...2 First steps...
Page 55: ...3 Fundamentals...
Page 126: ......
Page 127: ...4 Tools...
Page 165: ...5 Setup...
Page 245: ...6 Testing and running...
Page 311: ...7 Special functions...
Page 316: ......
Page 317: ...8 Pallets...
Page 339: ...9 MOD functions...
Page 368: ......
Page 369: ...10 HEROS functions...
Page 470: ......
Page 471: ...11 Operating the touchscreen...
Page 488: ......
Page 489: ...12 Tables and overviews...