If Tablet Feeder is selected:
Where is the Valve Wired? -
Selecting the box will bring you
to a table showing all valve outputs. Find the valve that is con-
nected to the Tablet Feeder. Select the valve and select Done.
If No is selected:
Do You Have a Salt Water Chlorine Generator?
(requires a connected Hay-
ward TurboCell or AquaRite with HLAQRPCB communication board)
If Yes is selected:
Type of Cell?
Select the type of Hayward TurboCell that is installed
in your system.
Where is the Cell Located?
If an entry is already shown in the box,
touch the Advance button. If no entry is shown, selecting the box
will bring you to a table showing the detected cells. The OmniPL will
detect a directly connected TurboCell and/or a TurboCell that is con-
nected to an AquaRite (requires HLAQRPCB communication board).
The table will display “Main Panel” under device type for directly con-
nected TurboCells and “AquaRite”, if a AquaRite is used.
Percentage of Output?
The OmniPL can only generate chlorine
while the filter pump is operating. Set the percentage of run time
that you desire chlorine generation. Raise this value to generate more
chlorine. Lower this value to generate less.
Is pH Reduction Enabled?
Select Yes if you have a dispenser to lower pH connected to
the OmniPL.
If Yes is selected:
Are you Using Acid or CO2?
Select one.
How Many Acid/CO
2
Dispensers?
Select the number of Acid/CO
2
dispensers
in your system.
Which relay is it Wired to?
Select the box to advance to the High Voltage Table.
This table lists all of the high voltage relays that are installed in the OmniPL.
Select the relay that is wired to the pH dispense unit. Refer to the Connection
Table for this information.
pH Setpoint
- Selecting the box will allow you to change the setpoint (7.5 de-
fault). Touch the Advance button when finished.
pH Dispensing Timeout
- Select a timeout interval. If the unit has been dis-
pensing for more than the selected timeout without reaching the desired level,
pH dispensing will turn off and an alarm will be displayed. Check the chemical
supply and the feeder. If both are OK, the timeout may need to be increased.
The user must clear the alarm to resume pH dispensing.
pH Extend Enabled
- If enabled, the OmniPL will continue to run the filter pump
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
38