Hayward Variable Speed Pump (VSP) Wiring
For pump models with dip
switches, set all switches to OFF
position (as shown). Remove
the display cable. Use the spare
connector taped to the display
cable for the communication
cable connection.
1 2 3 4
Low Speed Bus
2
3
A
B
4
COM
TriStar VS 900, Super Pump VS 700, MaxFlo VS 500
3 conductor
communication cable
Input Power
Input Power
bare wire
Tristar VS 950
(after Jan 2019)
2
3
4
A
B
COM
3
2
COMBUS
WALL MOUNT DISPLAY
1
2
3
4
5
6
7
8
CAUTION
HIGH
VOLTAGE
M O T O R
RED
BLU
BLK
4
Tristar VS 950
7
8
bare wire
1
(before Jan 2019)
Input Power
Disconnect onboard display and set all dip-
switches to OFF position.
*
*
*
*
TriStar
®
VS 950 Omni
(before Jan 2019)
Super Pump
®
VS 700 Omni
MaxFlo VS 500 Omni
Pump Conn.
Hub Conn.
7
2
8
3
A
2
B
3
COM
4
TriStar
®
VS 900 Omni
Pump Model
TriStar
®
VS 950 Omni
(after Jan 2019)
1
4
*
VSP Communication Wiring Table
bare wire
If using a Hayward TriStar 950, TriStar 900, Super
Pump 700 or MaxFlo 500, the pump can be fully
controlled (schedules and speeds) by the OmniPL.
Refer to the VSP Communication Wiring table as
well as the diagrams below for low voltage com-
munication wiring instructions.
Up to three VSPs
can be controlled by the OmniPL.
21
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS