tured after June 2018, you can select Yes and the OmniPL will test your lights
to confirm. If your lights blink white after the test, you can enable Omni Direct
mode. If not, the UCL light will default to UCL Standalone mode. Refer to your
Universal ColorLogic manual for more information about each mode.
How Many Accessories?
Select the number of accessories that will be used for this Body of Water
only. You’ll have an opportunity to configure accessories for the spa and also the backyard at a later
point.
If “1”or more is selected:
Select and Configure Accessories
At this screen you can add, delete and configure
your accessories. Select the desired accessory, then touch the Advance button. When
finished configuring accessories, you’ll be returned to this same screen. Touch the Done
button and advance to the next section of configuration. Refer to the following information
when configuring accessories:
Type of Accessory?
Touch the box and select the type of accessory used. Choices are
Laminars, Jets, Blower and Other.
Name of Accessory -
Touch the box and use the keyboard to name the accessory.
Does Accessory Have a Pump?
Select whether the accessory has a dedicated pump.
If so, the OmniPL will turn this pump on when the accessory is scheduled to run.
If Yes is selected:
What Type?
Select the type of pump used. The choices are Single Speed, Two
Speed and VSP.
If single speed or two speed pump is selected:
Which Relay is it Wired to?
If using a single speed or two speed
pump, you’ll be asked which relay(s) is wired to the pump. If a value
is already shown in the box(es), advance to the next screen. If no
value is shown, selecting the box will bring you to a table showing all
detected relays. Select the proper relay(s) from the table and touch
the Done button. The relay(s) should now be shown in the box(es) and
you can advance to the next screen to continue the pump configura-
tion.
Would You Like to Enable Priming?
Select whether you want the
pump to prime when turned on. This will turn the pump on at high
speed for 3 minutes to establish normal water flow every time the
pump is activated after being off for at least 30 seconds. This option
only appears if the pump is configured as a 2-Speed pump.
If VSP is selected:
Which Hayward Unique Address?
If using a VSP for your accesso-
ry pump, you’ll be asked what is the Hayward Unique Address (HUA).
If a value is already shown in the box, advance to the next screen. If
no value is shown, selecting the box will bring you to a table showing
43