Min Filter Speed -
Select the minimum speed that the Filter Pump will run while
the heater is active.
Min Air Temperature -
Select the minimum air temperature that the heater will
be allowed to run at. This option is only available if the heater is configured as
a Heat Pump.
Priority Duration -
Select the number of hours that this heater will run before the
next priority heater turns on.
Pump -
Configure the boost pump for the heater. This option is only available if
the heater is configured as a Solar heater.
Valve -
Configure the heating valve, if used. This option is only available if the
heater is configured as a Solar heater.
Solar Sensor -
Configure the solar sensor. This option is only available if the
heater is configured as a Solar heater.
Delete a Heater -
From this screen, if you wish to delete a heater that is currently
configured, select the trash can on the right of the name of the heater that you wish
to delete.
If Chemistry is selected:
pH -
Once you select pH, all of the options for pH dispensing will appear on the next
screen. These options are as follows:
Reduction ON -
Select whether you want pH reduction to be enabled.
Chemical Type -
Select the type of chemical that is being dispensed (acid or
CO
2
).
pH Dispensers -
Configure the pH dispense unit.
pH Timeout -
Choose the pH timeout time.
pH Extend -
Select whether you want pH extend enabled for this Body of Water.
Chem Sense Module -
Once you select Chem Sense Module, you will be able to
select the HUA of your Chem Sense Module you are using from the next screen.
Chlorination -
A flow switch must be installed for this function. Once you select
Chlorination, all of the options for chlorination will appear on the next screen. These
options are as follows: