Main Service (Power to the Circuit Breaker Subpanel)
The OmniPL circuit breaker subpanel can accommodate up to 8 circuit breakers and is rated for
100A service. Run properly rated conductors (L1, L2, N, and ground) from the primary house electri-
cal panel to the main power connections on the OmniPL circuit breaker base. The connection at the
main house panel should be to a 240VAC circuit breaker rated at 100A maximum.
Grounding and Bonding
Connect a ground wire from the primary electrical panel to the OmniPL ground bus bar. Also ground
each piece of high voltage (120 or 240VAC) equipment that is connected to the OmniPL control
relays or circuit breakers. The OmniPL should also be connected to the pool bonding system by an
8AWG (6AWG for Canada) wire. A lug for bonding is provided on the outside/bottom of the OmniPL
enclosure.
Circuit Breaker Installation and Wiring
Circuit breakers are to be supplied by the installer. Refer to the circuit breaker chart below for a list
of suitable circuit breakers that can be used. Follow the code and the circuit breaker manufacturer’s
rating requirements regarding the size and temperature rating for wiring. Note that some pool
equipment may be required to be connected to ground fault circuit breakers—check local and NEC
(CEC) codes.
OmniPL Power
The OmniPL requires 120VAC, 5A
power to operate the control logic
circuits and the chlorinator. This
power should be connected to a
dedicated circuit breaker.
WARNING: 120VAC only (perma-
nent damage will occur if con-
nected to 240V)