Size of Body of Water
- Enter the Body of Water size in gallons. If you’re not certain the size
of your pool, refer to the chart on page 26 to help determine the pool capacity.
How Many Filter Pumps?
- This question is for THIS BODY OF WATER ONLY. For example: If you
have 2 pumps; one for the pool Body of Water and one for the spa Body of Water, you would answer
“1” to this question.
If “1”or more is selected:
Name Filter Pump
- Touch the box and use the keyboard to name the filter pump.
What Type
- Depending on your answer, the OmniPL will use one relay (single speed
pumps), two relays (two speed pumps) or the low speed communication bus (VSP pumps)
for pump control. Select the type of pump and advance.
If one speed or two speed pump is selected:
Which Relay is it Wired to?
If using a single speed or two speed pump, you’ll
be asked which relay(s) is wired to the pump. If a value is already shown in the
box(es), advance to the next screen. If no value is shown, selecting the box will
bring you to a table showing all detected relays. Select the proper relay(s) from
the table and touch the Done button to proceed. The relay(s) should now be
shown in the box(es) and you can advance to the next screen to continue the
pump configuration.
Filter Pump Off for Valve Change?
When Yes is selected, the pump will shut
off for 35 seconds whenever the valve(s) change position.
Flow Monitoring Enabled?
Requires use of a Hayward flow switch.
This fea-
ture will help protect the filter pump from damage due to no flow. When Yes is
selected, the OmniPL will monitor the state of water flow when the filter pump is
on. If no flow is detected for more than 15 minutes, the OmniPL will shut down
the pool pump and will indicate an error. The error will be cleared the next time
the pump is turned on.
Would You Like to Enable Priming?
Select whether you want the filter pump
to prime when turned on. This will turn the pump on at high speed for 3
minutes to establish normal water flow every time the pump is activated after
being off for at least 30 seconds. This option only appears if the filter pump is
configured as a 2-speed pump.
Freeze Protection Enabled?
Freeze protection is used to protect the pool and
plumbed equipment against freeze damage during cold temperatures. If freeze
protection is enabled AND the air temperature falls below the freeze threshold,
the OmniPL will turn on the filter pump to circulate the water. If two Bodies of
Water are configured, the valves will also alternate between the pool and spa
every 30 minutes and the filter pump will turn off while the valves are turning.
The chlorinator will not operate if freeze protection is the only reason the pump
is running.
If Yes is selected:
Freeze Protection Temperature?
Select the temperature to be
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
32
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS