Do you have a Sense & Dispense Module?
Select Yes if a Hayward HL-CHEM (sold separately)
is connected to the OmniPL.
If Yes is selected:
The next few screens will configure the OmniPL to use Sense and Dispense. The OmniPL
automatically detects smart components like the HL-CHEM, and assigns a Hayward
Unique Address. If multiple components are detected, the OmniPL will show a table of
devices and prompt you to select the proper device.
Which Hayward Unique Address?
If a Hayward Unique Address (HUA) is already shown
in the box, touch the Advance button. If no address is shown, selecting the box will bring
you to a table showing all detected Sense and Dispense devices. Select the HL-CHEM
from the table and touch the Done button to advance. The address should now be shown.
Touch the Advance button to continue configuring the OmniPL for use with the HL-CHEM.
Does ORP Control Chlorination?
If you say Yes to this, the HL-CHEM will constantly
measure ORP and will adjust the pool’s chlorine based on a predetermined setpoint that
you will select. The system will monitor ORP and automatically generate/dispense the
correct amount of chlorine to maintain a desired level. Alternatively, if you say No to this
question and select a TurboCell, the HL-CHEM will monitor ORP, but the amount of chlorine
generated will be based on a manual setting that you will select.
If Yes is selected:
ORP Setpoint
- Set the desired ORP level which is measured in mV. 650mV is
the default. The OmniPL will continuously measure ORP and generate/dispense
the proper amount of chlorine to maintain this setpoint.
ORP Timeout
- Select a timeout interval. If the OmniPL has been chlorinating
for more than the selected ORP timeout without reaching the desired level, the
chlorinator will turn off and display an alarm. The user must clear the alarm to
resume chlorination.
Type of Chlorinator?
Select the Hayward TurboCell model, liquid chlorinator or
tablet feeder that is installed in your system. A flow switch must be installed
when using a chlorinator.
If TurboCell model is selected (requires a connected Hayward Turbo-
Cell or AquaRite with HLAQRPCB communication board):
Where is the Cell Located?
If an entry is already shown in
the box, touch the Advance button. If no entry is shown, se-
lecting the box will bring you to a table showing the detected
cells. The OmniPL will detect a directly connected TurboCell
and/or a TurboCell that is connected to an AquaRite (requires
HLAQRPCB communication board). The table will display “Main
Panel” under device type for directly connected TurboCells and
“AquaRite”, if a AquaRite is used.
If Liquid Chlorinator is selected:
Select Relay -
Selecting the box will bring you to a table show-
ing all HV relays. Find the relay that is connected to the Liquid
Chlorinator. Select the relay and select Done.