regardless of schedule until the pH level in the pool has reached the setpoint.
How Many Cleaners?
- This question is for THIS BODY OF WATER ONLY. For example: If you have
2 cleaners; one for the pool Body of Water and one for the spa Body of Water, you would answer “1”
to this question.
If “1”or more is selected:
Select and Configure a Cleaner
At this screen you can add, delete and configure your
cleaner(s). Select the desired cleaner, then touch the Advance button. When finished
configuring cleaner(s), you’ll be returned to this same screen. Touch the Done button
to advance to the next section of configuration. Refer to the following information when
configuring cleaner(s):
Type of Cleaner?
Touch the box and select the type of cleaner used. Choices are Pres-
sure, Suction, Robotic and In-Floor.
Name of Cleaner -
Touch the box and use the keyboard to name the cleaner.
Does Cleaner Have a Pump?
Select whether the cleaner has a dedicated pump. If so,
the OmniPL will turn this pump on when the cleaner is scheduled to run.
If Yes is selected:
What Type?
Select the type of pump used. The choices are Single Speed, Two
Speed and VSP.
If single speed or two speed pump is selected:
Which Relay is it Wired to?
If using a single speed or two speed
pump, you’ll be asked which relay(s) is wired to the pump. If a value
is already shown in the box(es), advance to the next screen. If no
value is shown, selecting the box will bring you to a table showing all
detected relays. Select the proper relay(s) from the table and touch
the Done button. The relay should now be shown in the box(es) and
you can advance to the next screen to continue the pump configura-
tion.
Would You Like to Enable Priming?
Select whether you want the
pump to prime when turned on. This will turn the pump on at high
speed for 3 minutes to establish normal water flow every time the
pump is activated after being off for at least 30 seconds. This option
only appears if the pump is configured as a 2-speed pump.
If VSP is selected:
Which Hayward Unique Address?
If using a VSP for your cleaner
pump, you’ll be asked what is the Hayward Unique Address (HUA). If
a value is already shown in the box, advance to the next screen. If
no value is shown, selecting the box will bring you to a table showing
all detected devices. Select the proper HUA from the table and touch
the Done button. The address should now be shown in the box and
you can advance to the next screen to continue the VSP configura-
tion.
39
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS