pump to prime when turned on. This will turn the pump on at high
speed for 3 minutes to establish normal water flow every time the
pump is activated after being off for at least 30 seconds.
Water Feature Wired to a Relay?
Select whether the water feature requires the use of
a high voltage relay.
If Yes is selected:
Select Relay -
Touching the box will bring you to a table showing all detected
relays. Select the relay(s) that is connected to the water feature and touch the
Done button. The relay should now be shown in the box and you can advance
to the next screen to continue water feature configuration.
Does Water Feature have a Valve?
Select whether the water feature requires a valve to
change position when in use.
If Yes is selected:
How Many?
Select how many valves are used for the water feature.
Where is the Valve(s) Wired?
Selecting the box will bring you to a table show-
ing all detected low voltage relays. Select the relay(s) that is wired to the water
feature valve(s), then advance. The valve(s) should now be shown in the box.
Advance to the next screen to continue water feature configuration.
Freeze Protection Enabled?
Freeze protection is used to protect the pool and plumbed
equipment against freeze damage during cold temperatures. If freeze protection is en-
abled AND the air temperature falls below the freeze threshold (refer to pump configura-
tion), the OmniPL will turn on the water feature pump to circulate the water.
Do You Want to Configure Any Lights?
Select yes if you are using any type of pool or spa
lights. The options are UCL (14V), CL4.0 (115V), CL2.5 (14V), Incandescent, and Other. Transform-
ers powering Universal ColorLogic lights must all be connected to the same high voltage relay for
synchronization to function properly. If using Omni Direct mode, you must use an internal relay, not
an HLRELAYBANK.
If Yes is selected:
What Kind of Lights?
Touch the box to select the type of lights that will be used. The
options are UCL (14V), CL4.0 (115V), CL2.5 (14V), Incandescent, and Other.
Name the Group of Lights
- Touch the box and use the keyboard to name the lights.
How Many Relays are Lights Wired to?
Select the number of relays used by the lights.
Which Relay is it Wired to?
Touching the box(es) will bring you to a table showing all
detected relays. Select the relay(s) that are connected to the lights and touch the Done
button. The relay(s) should now be shown in the box(es) and you can advance to the next
screen to continue the configuration.
If UCL was previously selected:
Would you like to test for Omni Direct capability?
For UCL lights manufac-
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
42