IMPORTANT: To ensure proper operation, verify that the arrow on the flow switch points in the direc-
tion of water flow.
Electrical Wiring
The OmniPL requires both high and low voltage connections. Low voltage connections will be made
to actuators, sensors, remote keypad, etc. High voltage connections will be made to pumps, lights,
etc., as well as providing direct input power to the Control Center. Always:
-Ensure that Power is disconnected prior to performing any wiring
-Follow all local and NEC (CEC if applicable) codes
-Use copper conductors only
-Remove power to the OmniPL subpanel before removing the deadfront
Ground Bus
Bar
Bonding Lug
High Voltage
Relays
Flow Switch
Connectors
High Speed (HS)
Bus Connector
Low Speed (LS)
Bus Connectors
4 Temperature
Sensor Inputs
External Input
Interlock
2 Heater Outputs
2 Low Voltage
Outputs
4 Valve Outputs
Chlorinator
Cell Connector
Subpanel
Controller
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS