background image

 

Hayward Industries

400 Connell Drive, Suite 6100

Berkeley Heights, NJ 07922

Phone: (908) 355-7995

www.hayward.com

OmniPL

Pool Automation and Chlorination 

Installation Manual

 092764 RevA

HLBPRO4SW

HLBPLUS4W

®

Contents 

Before You Begin.........................2
Overview....................................3
Mounting Equipment..................6
Plumbing..................................10
Electrical Wiring........................14
Preparing Pool/Spa Water.........25
System Startup.........................28
Configuration............................28

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Summary of Contents for OmniPL HLBPLUS4W

Page 1: ...yward com OmniPL Pool Automation and Chlorination Installation Manual 092764 RevA HLBPRO4SW HLBPLUS4W Contents BeforeYouBegin 2 Overview 3 Mounting Equipment 6 Plumbing 10 Electrical Wiring 14 Prepari...

Page 2: ...ck this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying the equipme...

Page 3: ...se harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio o...

Page 4: ...ection Table 16 High Voltage Pool Equipment 17 Low Voltage Wiring 20 General Water Chemistry 25 Salt 26 System Startup 28 Startup and Configuration Wizard 28 Bodies of Water 31 Filter Pumps 32 Heaters...

Page 5: ...USB thumbstick to update firmware Tools Needed Phillips and flat screwdrivers Wire cutters and strippers Knife to cut conduit Drill and drill bits including 3 8 Pliers Level Accessory Products Order S...

Page 6: ...s can be added for up to 8 total control up to 4 automatic valve actuators including pool and spa valves water feature valves cleaner valves and more control up to 4 heaters or low voltage equipment i...

Page 7: ...ks or clogs in the pool spa plumbing A flow switch is required if using chemistry Sense and Dispense accessories Overview Before attempting to install the OmniPL familiarize yourself with the installa...

Page 8: ...ts must be put into Standalone default mode before disconnecting the Pro Logic The OmniPL can only control ColorLogic lights in Standalone mode Service Power from Main Panel OmniPL Wiring Panel Option...

Page 9: ...ht of the unit The Wir ing Panel mounting brackets require a total of 6 mounting bolts to fasten the Wiring Panel to the mounting surface In all cases the heat sink on the back of the Wiring Panel pan...

Page 10: ...enclosure so that the flip door is able to be opened fully Also be sure to allow enough clearance below the Controller to access the USB and Ethernet connectors For best viewing results position the C...

Page 11: ...a separate Neutral wire to power the Smart Relay This is not a concern if using 230 VAC Note that conduit and connections to the included plastic box must be non metallic Find a location within 15 ft...

Page 12: ...e of your pool models are shown below In addition to the chlorinator cell a plumbing kit P KIT must be purchased This kit contains the cell unions and flow switch Refer to page 13 for plumbing instruc...

Page 13: ...POOL SWEEP BOOST PUMP WATER FEATURE PUMP POOL SPA RETURN VALVE WATER FEATURE VALVE SPA SPA JET PUMP SPA BLOWER POOL SPA SUCTION VALVE CHECK VALVE POOL VACUUM VALVE MANUAL VALVE MANUAL VALVE MANUAL VAL...

Page 14: ...ate Heaters for Pool Spa Configuration These systems have 2 complete sets of equipment filter pump filter heater 1 set for the pool and the other set for the spa Refer to the diagram below FILTER HEAT...

Page 15: ...ater 6 If any water feature or pressure side cleaner boost pumps are used be sure to enable the in terlock feature see CONFIGURATION for details to ensure that the pumps operate only when the Pool Fil...

Page 16: ...AFTER the filter and heater If installed on a pool spa combination system the cell must be plumbed BEFORE the pool spa return valve in order to allow proper chlorination of both the pool and the spa...

Page 17: ...r to the Control Center Always Ensure that Power is disconnected prior to performing any wiring Follow all local and NEC CEC if applicable codes Use copper conductors only Remove power to the OmniPL s...

Page 18: ...connected to the pool bonding system by an 8AWG 6AWG for Canada wire A lug for bonding is provided on the outside bottom of the OmniPL enclosure Circuit Breaker Installation and Wiring Circuit breaker...

Page 19: ...use the table below To identify the various inputs outputs refer to the diagram on the side of the table After attaching equipment to the OmniPL fill in the appropriate information in the table Connec...

Page 20: ...e on page 16 WARNING Do not use the OmniPL to control an automatic pool cover Swimmers may become entrapped underneath the cover WARNING Do not use the OmniPL to control fire pits or fire features Two...

Page 21: ...hts built after June 2018 the transformer s can be wired to either an internal relay or a Smart Relay Refer to your Universal ColorLogic manual for more information about Omni Direct mode Hayward Vari...

Page 22: ...ded for 230 VAC wiring A white conductor is supplied if using 115 VAC input power Use the included wire nuts for wiring connections Use proper threaded strain relief fittings when attaching conduit to...

Page 23: ...There are rubber plugs covering USB port and Ethernet port on the bottom of the Con troller enclosure The Ethernet port is available if a wired connection to the access point is desired over the buil...

Page 24: ...ristar VS 950 7 8 bare wire 1 before Jan 2019 Input Power Disconnect onboard display and set all dip switches to OFF position TriStar VS 950 Omni before Jan 2019 Super Pump VS 700 Omni MaxFlo VS 500 O...

Page 25: ...of heater connections on the OmniPL Main Board Record all connections in the Connection Table External Input Interlock The External Input Interlock provides a means to turn the filter pump or other co...

Page 26: ...hernet port Router LAN port Connection to the web is optional If web enabled devices such as PCs laptops tablets or phones will be used to access the OmniPL an Ethernet or wireless connec tion must be...

Page 27: ...er feature in floor cleaner etc For installations with solar heating Hayward offers the AQ SOL KIT xx solar kit that contains a valve actuator and extra temperature sensor The xx indicates the valve t...

Page 28: ...pools up to 25 000 gallons 95 000 liters If enabled see Configuration Wizard this operation requires a low concentration of salt sodium chloride in the pool spa water The OmniPL automatically converts...

Page 29: ...to determine how much salt in pounds or Kgs should be added to reach the recommended levels Use the Pool Sizing Formula below measurements are in feet gallons and meters liters if pool size is unknown...

Page 30: ...backwashing or draining because of rain Salt is not lost due to evaporation Type of Salt to Use It is important to use only sodium chloride NaCl salt that is greater than 99 0 pure This can be found...

Page 31: ...ding to NEC and local codes 5 The OmniPL is properly grounded and bonded Firmware Upgrade The OmniPL s firmware is the basic operating system that runs the unit The OmniPL was shipped with the version...

Page 32: ...the Connection Table page 16 handy while configuring the OmniPL If you are asked a question and don t know the answer in many cases you ll be able to skip the question and proceed In some cases the C...

Page 33: ...en exiting See page 49 for a Quick Edit Guide Configuration Wizard Guide As you progress through the Configuration Wizard refer to the following information to help answer questions and make selection...

Page 34: ...wo bodies of water typically a pool and spa Select the number and advance You ll be brought to a screen where you can add delete or edit a Body of Water When initially configuring the OmniPL a will ap...

Page 35: ...f for 35 seconds whenever the valve s change position Flow Monitoring Enabled Requires use of a Hayward flow switch This fea ture will help protect the filter pump from damage due to no flow When Yes...

Page 36: ...etting sched ules for your pump Filter Pump Off for Valve Change When Yes is selected the pump will shut off for 35 seconds whenever the valve s change position Flow Monitoring Enabled Requires use of...

Page 37: ...r pump to turn on it will only delay the turn off time when the heater is operating Maximum Settable Temperature This is the maximum allowed setting for the heater regardless of its default range Ther...

Page 38: ...ed relays Select the low voltage relay that is wired to the heater refer to the Connection Table for this information then advance The relay should now be shown in the box Advance to the next screen t...

Page 39: ...a table showing all detected low voltage relays Select the relay that is wired to the solar valve then advance The relay should now be shown in the box Advance to the next screen to continue solar he...

Page 40: ...ual setting that you will select If Yes is selected ORP Setpoint Set the desired ORP level which is measured in mV 650mV is the default The OmniPL will continuously measure ORP and generate dispense t...

Page 41: ...of run time that you desire chlorine generation Raise this value to generate more chlorine Lower this value to generate less Is pH Reduction Enabled Select Yes if you have a dispenser to lower pH conn...

Page 42: ...d pump is selected Which Relay is it Wired to If using a single speed or two speed pump you ll be asked which relay s is wired to the pump If a value is already shown in the box es advance to the next...

Page 43: ...uration Would you like your valve s to cycle On and Off at a set interval If you would like the cleaner valve s to cycle to a set interval while cleaning select Yes Set the interval on the next screen...

Page 44: ...ump is activated after being off for at least 30 seconds This option only appears if the pump is configured as a 2 speed pump If VSP is selected Which Hayward Unique Address If using a VSP for your wa...

Page 45: ...nst freeze damage during cold temperatures If freeze protection is en abled AND the air temperature falls below the freeze threshold refer to pump configura tion the OmniPL will turn on the water feat...

Page 46: ...ed pump If so the OmniPL will turn this pump on when the accessory is scheduled to run If Yes is selected What Type Select the type of pump used The choices are Single Speed Two Speed and VSP If singl...

Page 47: ...o a table showing all detected relays Select the relay that is connected to the accessory and touch the Done button The relay should now be shown in the box and you can advance to the next screen to c...

Page 48: ...Body of Water will automatically have heating priority Select Shared Heater Valves Select Body of Water 1 s return valve Body of Water 2 s re turn valve and the Heater return valve in your system The...

Page 49: ...en configuring sensors Where is the Sensor Located Touch the box and go to the table showing the Bodies of Water and the Backyard Select the location where the sensor is installed What Type of Sensor...

Page 50: ...h the Done button The relay should now be shown in the box and you can advance to the next screen to continue the accessory configuration NOTE Do not use the OmniPL to control fire pits or any other f...

Page 51: ...tion Read through the description and make sure the equipment will function as desired If Equipment to Mode is selected With Equipment to Mode interlock affected equipment will activate deactivate bas...

Page 52: ...uide If additional pool or backyard equipment is added after initial configuration or you d like to make a change to an existing configuration setting re enter the Configuration Wizard and select Edit...

Page 53: ...Select the Body of Water that you would like to make changes to Both bodies of water will have the same equipment options for Quick Edit Body of Water is selected Select the Equipment that you would l...

Page 54: ...inute period See Operation manual for more information If Heaters is selected Add a Heater Pressing Add a Heater from this screen will take you through the full configuration for adding a new heater T...

Page 55: ...if you wish to delete a heater that is currently configured select the trash can on the right of the name of the heater that you wish to delete If Chemistry is selected pH Once you select pH all of th...

Page 56: ...ssing Add Cleaner from this screen will take you through the full configuration for adding a new cleaner These steps are described in the Configura tion Wizard portion of this manual Select a Cleaner...

Page 57: ...ire Type Change the type of water feature that is configured Waterfall Waterslide etc Pump Configure the water feature pump if used Relay Select the relay that the water feature is wired to This optio...

Page 58: ...is currently configured select the group and then select the trash can button next to it If Accessories is selected Add Accessory Pressing Add Accessory from this screen will take you through the full...

Page 59: ...d Standalone Light Pressing Add Standalone Light from this screen will take you through the full configuration for adding new lights These steps are described in the Configuration Wizard portion of th...

Page 60: ...er name is desired Location Select the location that the sensor is wired to Delete a sensor From this screen if you wish to delete a sensor that is currently configured select the trash can on the rig...

Page 61: ...to set a static ip ad dress for the OmniPL The OmniPL will default to a dynamic ip connection and display current network information such as the local gateway ip addresses If a static connection is d...

Page 62: ...cted Select Function There are 4 options available Equipment Pressing this button will bring you to a screen that shows all avail able equipment Select the desired equipment that you want to assign to...

Page 63: ...er For more information on authorized service centers please contact the Hayward Technical Service Support Center 61 Whitecap Road North Kingstown RI 02852 or visit the Hayward web site at www hayward...

Page 64: ...istered trademark and OmniPL is a trademark of Hayward Industries Inc 2020 Hayward Industries Inc All other trademarks not owned by Hayward are the property of their respective owners Hayward is not i...

Reviews: