The chlorinator will not operate if freeze protection is the only reason the pump
is running.
If Yes is selected:
Freeze Protect Temperature?
Select the temperature to be used for
freeze protection. Temperature is adjustable from 33ºF-42ºF (1ºC-
6ºC). 38ºF (3ºC) is default. This threshold will be used for all outputs
that have freeze protection enabled.
Freeze Protect Speed?
This is the speed of the pump while freeze
protection is active. Select the desired pump speed %.
How many Heaters?
This question is for THIS BODY OF WATER ONLY. For example: If you have
2 heaters, one for the pool Body of Water and one for the spa Body of Water, you would answer “1”
to this question.
If “1”or more is selected:
Heater Cooldown Enabled?
This feature ensures that the heater cools down before wa-
ter circulation is stopped. When enabled, the OmniPL will continue to run the filter pump
for 5 minutes after the heater turns off.
Heater Extend Enabled?
If “Enabled”, the filter extend logic keeps the filter pump run-
ning beyond the normal turn-off time until the pool (or spa) is heated up to the desired
temperature setting. Heater extend will NOT cause the filter pump to turn on, it will only
delay the turn off time when the heater is operating.
Maximum Settable Temperature?
This is the maximum allowed setting for the heater
regardless of its default range. There may be circumstances where you will want to limit
the high temperature of your heater to a temperature that is lower than the factory high
setting.
Select and Configure a Heater
At this screen, you can add, delete and configure your
heater(s). Select the desired heater, then touch the Advance button. When finished con-
figuring heater(s), you’ll be returned to this same screen. Touch the Done button and
advance to the next section of configuration. Refer to the following information when
configuring heater(s):
What Type?
Heater choices are Solar, Heat Pump and Gas. Make your selection and
advance.
If Gas Heater is selected:
Name Heater
Select the box, then type the desired name for your heater. This
name will be used when referring to this particular heater.
Which Relay is it Wired to?
Selecting the box will bring you to a table showing
all detected relays. Select the low voltage relay that is wired to the heater (refer
to the Connection Table for this information), then advance. The relay should
now be shown in the box. Advance to the next screen to continue gas heater
configuration.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS