If Solar is selected:
Name Heater
Select the box, then type the desired name for your heater. This
name will be used when referring to this particular heater.
Does the Solar Heater Have a Pump?
Select whether the solar heating sys-
tem has a dedicated recirculation pump. If so, the OmniPL will turn this pump
on when the pool temperature is below the heater setting and there is solar heat
available.
If Yes is selected:
Which Relay is it Wired to?
Selecting the box will bring you to a
table showing all detected relays. Select the high voltage relay that
is wired to the heater (refer to the Connection Table in for this infor-
mation), then advance. The relay should now be shown in the box.
Advance to the next screen to continue solar heater configuration.
Does the Solar Heater Have a Valve?
Select whether the solar heating sys-
tem has a diverter valve to route pool/spa water through the solar collectors.
If so, the OmniPL will rotate this valve when the pool temperature is below the
heater setting and there is solar heat available.
If Yes is selected:
Where is the valve wired?
Selecting the box will bring you to a
table showing all detected low voltage relays. Select the relay that
is wired to the solar valve, then advance. The relay should now be
shown in the box. Advance to the next screen to continue solar heat-
er configuration.
Where is the Solar Temperature Sensor Located?
Selecting the box will
bring you to a table showing all detected sensors. Select the solar sensor
(usually SENS3), then advance. The sensor should now be shown in the box.
Advance to the next screen to continue solar heater configuration.
If more than one heater has been configured for this Body of Water:
Heater Priority Level?
Because more than one heater is configured
to heat this Body of Water, you can set the Priority for which heater
you’d like to use first (selection “1”). If the priority heater can’t meet
the demand, the next heater will start (selection “2”).
Heater Priority Duration?
Set the amount of time that you will allow
the priority heater (“1”) to heat before allowing the next heater to
start. If the priority heater meets the demand within this time frame,
the next heater will not be used.
Minimum Operation Speed?
Select the lowest pump speed that is allowed
while solar heating. Set a speed that will ensure that there will be sufficient flow
for the solar heating system to operate properly.