SECTION 3 –
CAB
3-48
•
Ensure the rinse, agitation, and solution
tank valves are CLOSED.
NOTE: Press and hold the Agitation Valve
Switch (located on the side console)
in the DOWN position for
approximately 10 seconds to ensure
the agitation valve is closed.
NOTE: These valves do not need to be
closed in order for the system to
operate, but are required for the Air
Purge to function properly.
•
Press the Air Purge Button (located on
the Auxiliary Controls Page).
•
On the “Air Purge” screen, press the
Manual Button.
•
On the “Air Purge” screen, press the Air
Button.
NOTE: When the Air Button is depressed, it
will open the air valve, releasing air
into the solution system.
•
Press the Master Spray Switch (located
on the Hydrostatic Drive Control Handle)
in the ON position.
•
Press the desired Boom Solution Valve
Switches (located on the side console) to
blow air and product out of the spray
system.
Automatic Mode
In Automatic Mode, the air tank on the
machine is filled based on engine speed and
time to automatically recharge the air tank
and purge the spray system.
Automatic Air Purge Settings
(Full Boom Purge, Individual Section Purge, Air
Recharge Time, and Minimum Engine Speed)
Full Boom Purge
•
Press the Air Purge Button (located on
the Settings Page).
Air Purge Button
(Located on the Auxiliary Controls Page)
Air Purge Screen
Air Purge Screen
Air Purge Button
(Located on the Settings Page)