3-43
SECTION 3 –
CAB
When conditions are met again, AWS will
automatically activate and the AWS indicator
will illuminate.
NOTE: The machine will automatically
determine if the proper conditions
have been met and change the
status of the drive functions.
Shutoff Speed for AWS
NOTE: AWS Shutoff speed default is set to
10 mph (16 km/h).
•
Press the Field Speed Settings Adjust
Button (located on the Settings Page).
•
On the “Adjust Field Speed Settings”
screen, press EDIT (next to AWS Shutoff
Speed).
•
Enter desired value.
•
Press ACCEPT.
•
Press OK.
Refer to “All-Wheel Steer” provided in the
Engine and Drive Systems Section
elsewhere in this manual for complete
operating instructions and safety
precautions.
Auto Steer
Steering Angle Sensor Absolute
(SASA)
The absolute value of the steering wheel
angle.
SASA T-Delay ON
Amount of time (in milliseconds) that the
steering wheel must NOT move before Auto
Steer can engage.
NOTE: The operator must engage Auto
Steer through the foot pedal/end row
management switch/auto steer
controller display to engage Auto
Steer after the steering wheel is not
moving.
SASA T-Delay OFF
Amount of time (in milliseconds) that the
steering must move before Auto Steer will
disengage.
NOTE: Auto Steer will disengage if active/
on.
NOTE: Default is set to 70 ms (less than 0.1
seconds) for both delay On/Off
modes.
A-Steer Sensitivity
How much the steering wheel must move
to disable Auto Steer.
NOTE: A larger sensitivity number means
that the steering wheel will need to
be turned farther and faster for Auto
Steer to disengage.
NOTE: Auto Steer sensitivity (that forces
Auto Steer off directly from steering
wheel movement) may be adjusted
when switching from floater tires to
row crop tires, or vice versa.
To Change Auto Steer Setting Values
•
Press the Auto Steer Button (located on
the Settings Page).
Field Speed Settings Adjust Button
(Located on the Settings Page)
Adjust Field Speed Settings Screen