SECTION 8 –
DUAL PRODUCT SPRAY SYSTEMS
8-4
Refer to “Draining Your Solution Tank”
elsewhere in this section for further
information.
Solution Tank Valves (2)
The Solution Tank Valves - Tanks 1 and 2
(located beneath the solution tank on
underside of machine) are electric tank shut-
off valves. These valves are controlled by the
Main Tank Valve Switch (located on the side
console).
Main Tank Valve Switch
The Main Tank Valve Switch (located on
the side console) controls both of the solution
tank valves for Tanks 1 and 2.
•
Press the Main Tank Valve Switch in the
UP (On) position to open the solution
tank valves.
•
Press the Main Tank Valve Switch in the
DOWN (Off) position to close the solu-
tion tank valves.
NOTE: Main Tank Valve status (OPEN or
CLOSED) is displayed on the
Machine Display Home Page - Field
Mode.
Agitation Valves
(Electrical Actuation and Manual Shutoff)
The flow rate of the Agitation System is
controlled by the Agitation Valve (located
beneath rear of machine) to thoroughly mix
solution in the tank and regulate pressure
and flow to the jet agitators. Increase or
decrease agitation flow by operating the
Agitation Valve Switch (located on the side
console).
• Solution Tank
Valve - Tank 1
(1000-gal./3785L)
• Solution Tank
Valve - Tank 2
(600-gal./2271L)
Solution Tank Valves - Tanks 1 and 2
(Located beneath the solution
tank on underside of machine)
-Typical View
Main Tank Valve Switch
(Located on the side console)
-Typical View
Main Tank Valve Status Indicator
(Located on the Machine Display