SECTION 9 –
MAINTENANCE AND STORAGE
9-20
6. Wipe off any loose debris around the fil-
ter housing using a clean cloth.
NOTE: DO NOT used compressed air to
clean the filter housing.
7. Before installing the new filter, inspect
the RESPA Cab Filtration System and
replacement filter for proper operation.
8. Turn RESPA Filtration System ON, stay-
ing clear of the open end of the filter
housing.
9. Ensure adequate airflow is blowing out
of the empty filter housing.
10. Turn RESPA Filtration System OFF.
11. Install new filter.
NOTE: Ensure new filter ejection port
orientation is correct and the filter
end cap is properly seated on the
filter housing (with the gills pointing
downward to avoid water from
entering in).
12. Re-latch the four (4) Filter Latches.
Refer to your Parts Manual for
replacement part number.
Charcoal Filter
Remove and replace the Charcoal Filter
at the first sign of chemical odor entering the
cab area, or every 500 hours of operation at
a minimum. Refer to your Parts Manual for
replacement part number.
Accessing the Charcoal Filter
1. Loosen the top metal Flange Clamp
(located near the top of the RESPA filtra-
tion unit).
2. Separate the RESPA filter housing from
the vent tube.
3. Remove the four (4) Mounting Bolts (two
located on each side of access panel on
the right-hand side of cab) and set aside.
4. Carefully lower access panel/filter
assembly to the ground.
Flange Clamp - Top
(Located near the top of
the RESPA filtration unit)
-Typical View
Mounting Bolts (4)
(Two located on each side of access
panel on the right-hand side of cab)
-Typical View