GBC FusionPunch II Service Manual
RAP 1.2 AC Power to the Stacker
12/2003
2-6
Check continuity between P8 and the
Stacker O-Ring Motor. If the harness is
OK, replace the Stacker O-Ring Motor (PL
1.2B).
9.
The Stacker Bypass Motor does not run.
On the problem Stacker AC/DC Distribution
PWB, disconnect P/J 10 to the Stacker
Bypass Motor. Activate the Bypass Motor
using the information in the table below.
**Only on Stackers with Bypass installed.
With the output active, check for 108 VAC
to 120 VAC between J10-NUI and J10-
RMTR.
There is 108 VAC to 120 VAC between
these points.
Y
N
Replace the Stacker AC/DC
Distribution PWB (PL 3.2) in the
problem Stacker.
Check continuity between P10 and the
Stacker O-Ring Motor. If the harness is
OK, replace the Stacker Bypass Motor (PL
1.3A).
Stacker 1
Bypass
Motor**
S1 OUTB2 StackBypass
O10 0000000000000000
Stacker 2
Bypass
Motor**
S2 OUTB2 StackBypass
O10 0000000000000000
Summary of Contents for FusionPunch II
Page 10: ...GBC FusionPunch II Service Manual GBC Training Process 12 2003 1 6 Notes ...
Page 24: ...GBC FusionPunch II Service Manual Final Actions 12 2003 1 20 Notes ...
Page 80: ...GBC FusionPunch II Service Manual RAP 6 2 Printer Connectivity 12 2003 2 56 Notes ...
Page 324: ...GBC FusionPunch II Service Manual Host Machine Enablement DocuColor 6060 12 2003 6 52 ...
Page 332: ...GBC FusionPunch II Service Manual Notes 12 2003 6 60 Notes ...
Page 354: ...GBC FusionPunch II Service Manual Principles of Operation 12 2003 6 82 Notes ...
Page 364: ...GBC FusionPunch II Service Manual Tag Numbers 12 2003 6 92 ...
Page 402: ...GBC FusionPunch II Service Manual Component Locators 12 2003 7 38 Notes ...
Page 414: ...GBC FusionPunch II Service Manual Preparing to Install a Bypass Kit 12 2003 8 12 Notes ...
Page 430: ...GBC FusionPunch II Service Manual Notes 12 2003 8 28 Notes ...