REP 5.4 Bypass Gate Fingers
GBC FusionPunch II Service Manual
12/2003
4-21
REP 5.4 Bypass Gate Fingers
Parts List: 5.2 A
Prerequisite
Lower the Stacker Tray.
WARNING
Switch off the Main Power.
Disconnect the power cord.
Removal
1.
Open the Stacker Top Cover and Front
Door.
2.
Make marks on the Bypass Gate Shaft
(Figure 1).
3.
Loosen:
3.1 the 7 Allen screws in the 7 Gate
Fingers.
3.2 the Allen screw in the Bearing Collar
(Figure 1).
NOTE: Ensure that the setscrews in
the Gate Fingers are loosened enough
to clear the round part of the shaft.
4.
Remove the Bearing Collar.
5.
Slide the Bypass Gate Shaft towards the
back of the machine until you can remove
the Gate Fingers (Figure 1).
Replacement
1.
Reinstall the parts in the reverse order.
2.
Perform ADJ 5.4 Bypass Gate Solenoid and Gate Fingers.
MARK THE
GATE SHAFT
BEARING
COLLAR
Figure 1.
Summary of Contents for FusionPunch II
Page 10: ...GBC FusionPunch II Service Manual GBC Training Process 12 2003 1 6 Notes ...
Page 24: ...GBC FusionPunch II Service Manual Final Actions 12 2003 1 20 Notes ...
Page 80: ...GBC FusionPunch II Service Manual RAP 6 2 Printer Connectivity 12 2003 2 56 Notes ...
Page 324: ...GBC FusionPunch II Service Manual Host Machine Enablement DocuColor 6060 12 2003 6 52 ...
Page 332: ...GBC FusionPunch II Service Manual Notes 12 2003 6 60 Notes ...
Page 354: ...GBC FusionPunch II Service Manual Principles of Operation 12 2003 6 82 Notes ...
Page 364: ...GBC FusionPunch II Service Manual Tag Numbers 12 2003 6 92 ...
Page 402: ...GBC FusionPunch II Service Manual Component Locators 12 2003 7 38 Notes ...
Page 414: ...GBC FusionPunch II Service Manual Preparing to Install a Bypass Kit 12 2003 8 12 Notes ...
Page 430: ...GBC FusionPunch II Service Manual Notes 12 2003 8 28 Notes ...