[PSA installation folder]\opt\FJSVpsa\sh\setpsalan.bat
Note
If the operating system has not been restarted after PSA installation, the PSA-to-MMB communication LAN
setting command in step 1 will fail.
Execute the PSA-to-MMB communication LAN setting command after restarting the operating system.
2. Restart the operating system.
Performing the above procedure sets the following values.
<IP address>
172.30.0.<
partition ID
+ 2>/24
Example: Partition ID of 2
172.30.0.4/24
<Communication settings>
Auto Negotiation off
Speed 100 Mbps
Duplex full
In the following cases, change the IP addresse setting.
- The automatically set IP address is the same as the IP address or subnet used for a production network or
management network.
- You are configuring a new partition using a duplicate disk from another partition.
- The partition ID changes because a disk installed in a partition was moved to another partition.
- You are configuring a Windows cluster (MSCS) with partitions assigned the same number, with the cluster
spanning cabinets. (The same IP addresses are assigned, so a configuration check detects an error indicating
that a duplicate IP address was found.)
Change the IP address setting by using the following procedure. If you are changing the setting because of the above
reason 1, you need to change the IP addresses of all partitions in the cabinet and the IP address of the PSA-to-MMB
communication LAN on the MMB side to IP addresses in the same subnet. Change the IP addresses on the MMB
side from the MMB Web-UI.
Notes
- Do not change the automatically set communication values. Otherwise, PSA-MMB communication may be
disabled, making PSA functions unavailable.
- Change PSA-to-MMB LAN settings only after PSA installation. If changed before PSA installation, the
settings are overwritten by the installation.
Configuring the network adapter for the PSA-to-MMB communication LAN
Configure the network adapter by using the following procedure.
Operations
1. Select [Control Panel] - [Network Connections].
>> A window displays a list of networks.