- Operations management software cannot collect information on the partition side.
- Even under an REMCS agreement, no software errors are reported.
- Hot maintenance of hard disks is disabled. The partition must be stopped for maintenance.
- PRIMECLUSTER linkage is disabled.
Remarks
- SVIM installs PSA as it installs the operating system. For details on SVIM, see the
ServerView Suite
ServerView Installation Manager
.
- For details on how to manually install PSA, see
APPENDIX B Manual PSA Installation and
- The following table lists settings for PSA operation. The installer automatically adds or updates these settings
during PSA installation.
TABLE 6.3 Settings automatically added/changed during PSA installation
Target
Action
Remarks
syslog.conf file
Add setting
snmpd.conf file
Add setting
snmptrapd.conf file
Add setting
services files
Add setting
Added port: The installer does not check for
duplicate port numbers when a setting is added to
the fj-webgate (24450) services file. Change
settings as needed.
snmptrapd start option
Change
snmpd start option
Change
Dedicated PSA-to-MMB
communication LAN interface
Set IP address
6.2.1 Configuring the PSA-to-MMB
iptables setting
Add setting
SELinux configuration file
(/etc/selinux/config)
Change
SELinux is disabled only for RHEL5. If SELinux
is disabled, do not change the settings.
SELinux setting
Add setting
The policy module is added for RHEL6 or later
only.
Note
If you change the IP address of the dedicated PSA-to-MMB communication LAN on the MMB side or partition
side, you need to then restart PSA. Otherwise, a display error may occur in the [PSA] window of the MMB Web-
UI. Moreover, PSA would not be able to report any detected errors.
6.2.1
Configuring the PSA-to-MMB communication LAN
This section describes how to confirm the settings for the PSA-to-MMB communication LAN.
Communication between PSA and the MMB requires an active NIC (network interface card) connected to the PSA-
to-MMB communication LAN.
PRIMEQUEST 1000 Series Installation Manual
CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E)
130