- Execute the SNMP security setting command (setsnmpsec) in the following situations. For details on the
command, see 4.8 SNMP Security Setting Command (setsnmpsec) in the
PRIMEQUEST 1000 Series Tool
Reference
(C122-E110EN).
- Having installed PSA, you will be changing the SNMP Service security setting from [Accept SNMP
packets from any host] to [Accept SNMP packets from these hosts].
- You will be changing the MMB IP address.
- In the initial startup of PSA following installation, the Web-UI may display the error message "E_33077 PSA
is Not Active. (01:0000)" in the [PSA] window. This happens because PSA requires extra time to acquire
system sensor data only during the initial startup. Wait a few minutes. Then, refresh the display.
- If you change the MMB IP address or the management LAN IP address on the partition, be sure to then restart
PSA. Otherwise, a display error may occur in the [PSA] window of the Web-UI. Moreover, PSA would not
be able to report detected errors.
Notes on configuring Windows Server 2003
- Do not enable [Visual Notification] in the options of Dr. Watson (diagnosis software bundled with Windows).
Otherwise, if a PSA error occurs, a message box appears. You cannot restart PSA until you close this box.
- From [Properties] in the Event Viewer, do not change the operation in [When maximum log size is reached]
for the system log or application log to [Do not overwrite events (clear log manually)]. Otherwise, after the
log reaches the maximum log size, no errors are output to the log, so PSA will be unable to detect any errors.
- Do not stop the Windows Print Spooler service. The information collection function of the operating system
uses WMI (Windows Management Instrumentation). If the Print Spooler service is stopped, the function
cannot collect the correct configuration information because WMI reports an error.
- If the set value of the following registry key is less than 20000 (20 seconds), the system may hang during
operating system shutdown. Be sure to set a value equal to or greater than 20000 (20 seconds). The default
is 20000.
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\
WaitToKillServiceTimeout
You can use the above registry key to specify the wait time (ms) before the service is terminated in the
shutdown sequence.
6.3.1
Configuring the PSA-to-MMB communication LAN
This section describes how to confirm the settings for the PSA-to-MMB communication LAN.
Communication between PSA and the MMB requires that the partition have an active NIC connected to the PSA-
to-MMB communication LAN.
For the setting of the PSA-to-MMB communication LAN, use the following procedure.
Note
In the following cases, you can use neither the screen display nor event notification function of PSA:
- [Interface] of [MMB-PSA IP Address] in the [Network Configuration] - [Network Interface] window of the
MMB Web-UI is Disable
- The following operation (execution of the configuration command of PSA-to-MMB communication LAN)
is not performed
1. Execute the PSA-to-MMB communication LAN setting command.
PRIMEQUEST 1000 Series Installation Manual
CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E)
151
C122-E107-09EN