Operating
8.5
Start after a service
5.
Read the oil level. The line in the middle of the
sight glass shows the minimum level. Refill if
necessary. For grade and quality of oil see
5.9
Lubricants on page 59
.
Check the oil level
Rotation Direction
Check the rotation of the bowl by doing a quick
start/stop. The motor fan must rotate in a
clockwise direction.
!
CAUTI
ON
If power cable polarity has been reversed, the
separator will rotate in reverse, and vital rotating parts
can loosen.
P003596B
!
WARN
ING
Disintegration hazards
After change of feed the sludge discharge interval
must be adjusted.
Too long intervals between discharges can result in
breakdown.
!
CAUTI
ON
Burn hazard
Avoid contact with hot surfaces. Process pipes,
various machine surfaces, and processed liquid can
be hot and cause burns.
P004073C