[email protected]
whatsapp:959440045
6.4
Flat belt and tightener
6
Dismantling & Assembly
6.4
Flat belt and tightener
The flat belt must be removed before dismantling
of the bowl spindle or the friction coupling.
The procedure is the same when replacing the
belt at a Major Service. A new belt must be
re-tightened twice:
•
30 minutes after the belt has been installed.
The separator must not be started until the
re-tightening has been done.
•
after approximately 24 hours of operation.
NOTE
Do not start the separator unless the flat belt has been
re-tightened after 30 minutes. If started, the belt may
slip and be damaged.
6.4.1
Belt replacement and tightening
If only tightening of flat belt should be done, only
steps 3 and 8-12 have to be performed.
!
WARN
ING
Entrapment hazards
Make sure that rotating parts have come to a complete
standstill before starting any dismantling work.
Look into the slot in the frame hood to see if separator
parts are rotating or not.
G0467361
1.
Remove the water tank and brake. Note that
the tank must be lowered past spindle end (A)
before it can be withdrawn (B).
G0884721
122
www.fdm.com.pe