[email protected]
whatsapp:959440045
2
Safety instructions
Disintegration hazards
•
When power cables are connected, always
check direction of motor rotation. If incorrect,
vital rotating parts could unscrew.
•
If excessive vibration occurs, stop separator and
keep bowl filled with liquid during rundown.
•
Use the separator only for the purpose and
parameter range specified by Alfa Laval.
•
Check that the gear ratio is correct for power
frequency used. If incorrect, subsequent
overspeed may result in a serious break down.
•
Welding or heating of parts that rotate can
seriously affect material strength.
•
Wear on the large lock ring thread must not
exceed safety limit.
Φ
-mark on lock ring must not
pass opposite
Φ
-mark by more than specified
distance.
•
Inspect regularly for
corrosion
and
erosion
damage. Inspect frequently if process liquid is
corrosive or erosive.
12