3.6 Lubrication and maintenance operations
3.6.28 Gas line hose replacement
Perform gas line hose replacement when the machine is parked
on a flat and solid surface with the engine and battery discon-
necter off and with the closed gas bottle shut-off valve.
Have the gas line hose replacement performed by an authorised
service plant or qualified personnel.
Gas line hose removal procedure:
• Close the gas bottle (2) shut-off valve (1).
• Remove the gas line hose (3) from the safety valve (4).
• Remove the gas line hose (3) from the solenoid valve of the
gas supply (5).
• Remove the gas line hoses (6) from the gas supply distrib-
utor (7).
• Remove the gas line hoses (6) from the burners (8).
Gas line hose mounting procedure:
• Mount the new gas line hoses (6) on the burners (8).
• Mount the new gas line hoses (6) on the gas supply distrib-
utor (7).
• Mount the new gas line hose (3) on the solenoid valve of the
gas supply (5).
• Mount the new gas line hose (3) on the safety valve (4).
Procedure to check the hoses of the gas distribution for
leakage.
• Perform the gas equipment tightness check according to
Chapter 3.6.8.
• In case you detect a leak on the gas system again, repeat the
gas equipment tightness check procedure.
Perform gas line hose replacement when the machine is
parked on a flat and solid surface with the engine and
battery disconnecter off and with the closed gas bottle
shut-off valve.
The machine must be equipped with a fire extinguisher.
Have the fire extinguisher ready on the driver's stand at
a place intended for this purpose.
Pay extra attention to potential gas leaks
and in doubt,
shut off the gas supply.
Check the tightness of the gas equipment, e.g. with a gas
leak detector.
If you detect gas leakage, immediately shut off the
gas bottle shut-off valve and have the gas equipment
repaired by an authorised service plant or qualified
personnel.
Follow safety regulations for handling gas bottles.
There is a risk of burns. Use protective equipment.
Have the gas equipment tightness check performed by
an authorised service plant or qualified personnel.
Summary of Contents for Dynapac F80W
Page 1: ...OPERATING MANUAL Asphalt paver wheeled F80W Hatz 4812217930 ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 14: ...8 F80W ...
Page 15: ...9 F80W SPECIFICATION MANUAL 1 SPECIFICATION MANUAL F80W Hatz Tier 4 Final ...
Page 18: ...12 F80W W1 W2 W W3 W4 B L L1 H H1 D451170A A L2 1 2 Dimensional drawing of the machine ...
Page 32: ...26 F80W Notes ...
Page 33: ...27 F80W SPECIFICATION MANUAL Notes ...
Page 34: ...28 F80W ...
Page 35: ...29 F80W OPERATING MANUAL 2 OPERATING MANUAL F80W Hatz Tier 4 Final ...
Page 62: ...56 F80W ...
Page 79: ...73 F80W 451043 451044 D451042 OPERATING MANUAL Augers Screed Conveyor ...
Page 123: ...117 F80W OPERATING MANUAL Notes ...
Page 124: ...118 F80W ...
Page 125: ...119 F80W MAINTENANCE MANUAL 3 MAINTENANCE MANUAL F80W Hatz Tier 4 Final ...
Page 126: ...120 F80W ...
Page 191: ...185 F80W 451190 MAINTENANCE MANUAL ...
Page 193: ...187 F80W 451900 1 1 1 11 5 A 12 V 2 2 10 12 3 3 3 4 5 4 6 7 8 9 8 MAINTENANCE MANUAL ...
Page 196: ...190 F80W 3 8 Appendices Notes ...
Page 197: ......
Page 198: ...www dynapac com ...