ENVR208
Step 8
Click
Apply
.
12.6 Region Exiting Detection
Purpose:
Region exiting detection function detects objects that exit from a pre-defined virtual region.
Step 1
Go to
System > Event > Smart Event
.
Step 2
Click
Region Exiting
.
Figure 12-6
Region Exiting Detection
Step 3
Select a
Camera
to configure.
Step 4
Check
Enable Region Exiting Detection
.
Step 5
Optionally, check
Save VCA Picture
to save the captured pictures of region exiting detection.
Step 6
Follow the steps to set the detection rules and detection areas.
1)
Select an Arming Region to configure. Up to 4 regions are selectable.
2)
Drag the sliders to set Sensitivity.
Sensitivity:
The higher the value is, the more easily the detection alarm can be triggered.
Its range is [0-100].
3)
Click Draw Region and draw a quadrilateral in the preview window by specifying four
vertexes of the detection region.
Step 7
Set the arming schedule. Refer to Chapter 11.1 Configure Arming Schedule.