![EDM Solution 862 Installation Manual Download Page 59](http://html1.mh-extra.com/html/edm/solution-862/solution-862_installation-manual_2362278059.webp)
System Operations
59
Codepad Duress Alarm
A codepad duress alarm is used as a silent hold up alarm. This will only occur when the
number
9
is added to the end of any valid user code that is being used to disarm the system.
However, if a user code has a priority level of arming only, entering their user code followed
by 9 will still transmit a duress alarm when the system is armed.
A duress alarm (Contact ID Event Code 121) is only useful if your system is reporting back to
a monitoring station or pocket pager as domestic reporting format can’t decipher which type of
alarm had occurred. If you wish to disable the codepad duress alarm report, refer to
“LOCATION 336” on page 180 for more information. If you require to activate a duress alarm
by adding a number 3 to the end of any valid user code being used to disarm the system, enable
Option 2 in “LOCATION 430” on page 221.
+
9
+
Codepad Panic Alarm
and
3
buttons
or bot
An audible codepad panic alarm will be activated when both the
1
h the
and
buttons are pressed simultaneously.
Refer to Option 1 in "LOCATION 425" on page 216 if you wish to program codepad
panic to be silent. If you wish to disable the codepad panic alarm report, refer to
“LOCATION 337 - 338” on page 180 for more information. A codepad panic alarm
will transmit a Contact ID Event Code 120 when reporting back to a base station
receiver.
1
+
3
or
+
Codepad Fire Alarm
An audible codepad fire alarm will be activated when both the
4
and
6
buttons on
the remote codepad are pressed simultaneously. A distinct fire sound is emitted
through the horn speaker to indicate this type of alarm condition. The fire sound is
different to the burglary sound.
Refer to Option 2 in "LOCATION 425" on page 216 if you wish to program codepad
fire to be silent. If you wish to disable the codepad fire alarm report, refer to
“LOCATION 339 - 340” on page 181 for more information. A codepad fire alarm
will transmit a Contact ID Event Code 110 to a base station receiver.
Figure 3: CP5 LED Codepad
Showing Audible Alarm Buttons
4
+
6
Codepad Medical Alarm
An audible codepad medical alarm will be triggered when both the
7
and
9
buttons on the
remote codepad are pressed simultaneously.
Refer to Option 4 in "LOCATION 425" on page 216 if you wish to program codepad medical
to be silent. If you wish to disable the reporting of the codepad medical alarm report, refer to
“LOCATION 341 - 342” on page 181 for more information. A codepad medical alarm will
transmit a Contact ID Event Code 100 to a base station receiver.
7
+
9
Electronics Design and Manufacturing Pty Limited
ISSUE130
Summary of Contents for Solution 862
Page 1: ...Solution 862 Installation Manual ISSUE 1 30...
Page 2: ......
Page 4: ......
Page 6: ......
Page 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 245: ...Programming Sheets...
Page 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 255: ...Index...
Page 262: ......