![EDM Solution 862 Installation Manual Download Page 145](http://html1.mh-extra.com/html/edm/solution-862/solution-862_installation-manual_2362278145.webp)
Dialler Options
145
Dialler Options 1
LOCATION 177
9
1
Dialler Reporting Functions Allowed
2
Remote Arming Via The Telephone Allowed
4
Answering Machine Bypass Only When Armed
8
Use Bell 103 For FSK Format (Disabled = CCITT V21)
1
2
4
8
Option
Description
Table 64: Dialler Options 1
Dialler Reporting Functions Allowed
If this option has been selected, the dialler will function for all operations. Upload/Download
via Alarm Link Software (CC816) and telephone remote arming will remain operational
regardless of this setting.
Disabled = Disable All Dialler Reporting Functions
If this option is not selected, the communication dialler will not operate. Upload/Download via
Alarm Link Software (CC816) and telephone remote arming will remain operational regardless
of this setting.
Remote Arming Via The Telephone Allowed
If this option has been selected, you can remotely arm the system via a standard telephone
using the Phone Controller (CC911) or by pressing the
*
button on your touch tone
telephone. Refer to Remote Arming Via The Telephone on page 112 for more information.
Forced arming is automatically assumed when this feature is being used. Refer to Zone
Options 2 on page 171 for more information on forced arming.
Whether remote functions have been enabled or disabled, this will have no effect on remote
arming via the telephone. Refer to Ring Count on page 140 for programming the number of
rings before the control panel will answer an incoming call.
Answering Machine Bypass Only When Armed
This option needs to be selected if the answering machine bypass feature is required to operate
only when the system has been armed in AWAY Mode, STAY Mode 1 or STAY Mode 2.
When the system is disarmed, the control panel will not answer any incoming calls. This
option is beneficial in high telephone traffic installations where the control panel could answer
an incoming call. Refer to Ring Count on page 140 to program answering machine bypass.
Use Bell 103 For FSK Format (Disabled = CCITT V21)
If this option is enabled, the control panel will use the transmission frequency BELL 103 at
300 baud. If this option is disabled, the control panel will use the transmission frequency
CCITT V21 at 300 baud.
Electronics Design and Manufacturing Pty Limited
ISSUE130
Summary of Contents for Solution 862
Page 1: ...Solution 862 Installation Manual ISSUE 1 30...
Page 2: ......
Page 4: ......
Page 6: ......
Page 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 245: ...Programming Sheets...
Page 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 255: ...Index...
Page 262: ......