Alarm Link Operations
115
Remote Connect Without Call Back Verification
Remote connect without call back verification can be handy where you have a need to perform
Upload/Download functions from multiple locations.
There are two methods that you may program so that the call back verification is disabled. It
should be noted that by using this feature you are reducing the security of the control panel.
Method One
Method one allows you to call the control panel from any remote location without the need of
having the control panel call back to the computer to establish a link. In using method one, the
customer has no access to initiate a modem call by holding down the
6
button. The following
locations need to be programmed for this method to operate.
"LOCATION 159 - 174" on page 139 should be programmed as zeros. Option 1 in
"LOCATION 180" on page 117/148 will need to be enabled and Option 2 needs to be disabled.
The control panel will now allow a connection of the first call without calling the remote
computer back to make contact.
Method Two
Method two allows you to program a call back telephone number so that the customer can still
initiate a modem call when required, but when calling the control panel via the computer from
any remote location, the control panel does not call back the remote computer to establish a
link.
"LOCATION 159 - 174" on page 139 should have the call back telephone number
programmed if required. Option 1 in "LOCATION 180" on page 117/148 will need to be
enabled and Option 2 needs to be disabled.
The control panel will now allow a connection of the first call without calling the remote
computer back to make contact but still allow the customer to initiate a modem call by holding
down the
6
button when required.
Remote Connect With Call Back Verification
Remote connect with call back verification offers the highest degree of data security by
incorporating a two level security check.
The first is the Installer Code combined with the Subscriber ID Number needs to match that of
the control panel. Secondly, the control panel will call back the programmed call back
telephone number to establish the valid connection. The "Call Back Telephone Number" is the
telephone line that the modem and computer has been connected to.
"LOCATION 159 - 174" on page 139 must be programmed with the Call Back Telephone
Number and both Option 1 and Option 2 in "LOCATION 180" on page 117/148 will need to
be enabled.
Electronics Design and Manufacturing Pty Limited
ISSUE130
Summary of Contents for Solution 862
Page 1: ...Solution 862 Installation Manual ISSUE 1 30...
Page 2: ......
Page 4: ......
Page 6: ......
Page 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 245: ...Programming Sheets...
Page 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 255: ...Index...
Page 262: ......