![EDM Solution 862 Installation Manual Download Page 23](http://html1.mh-extra.com/html/edm/solution-862/solution-862_installation-manual_2362278023.webp)
Programming
23
Programming With The Remote Codepad
When programming the control panel via the remote codepad, the system must be in the
disarmed state with no alarm memory present.
To access the Installer’s Programming Mode, enter the four digit
followed by
the
button. The factory default Installer Code is
1234
. Two beeps will be heard
and both the
AWAY
and the
STAY
indicators will flash simultaneously to indicate that you have
entered Installer’s Programming Mode.
When entering Installer’s Programming Mode, you will be automatically positioned at
“LOCATION 000”, the beginning of the Primary Telephone Number for Receiver 1.
Data
Value
Zone 1
Indicator
Zone 2
Indicator
Zone 3
Indicator
Zone 4
Indicator
Zone 5
Indicator
Zone 6
Indicator
Zone 7
Indicator
Zone 8
Indicator
MAINS
Indicator
0
1
V
2
V
3
V
4
V
5
V
6
V
7
V
8
V
9
V
V
10
V
11
V
V
12
V
V
13
V
V
14
V
V
15
V
V
Table 3: Codepad Indicators When Programming
Example
To access Installer’s Programming Mode, enter the
followed by the
button. Two beeps will be heard and both the
AWAY
and the
STAY
indicators will flash
simultaneously to indicate that you have entered Installer’s Programming Mode. The codepad
indicators will display the current data stored in the first location (LOCATION 000).
To move to another programming location, enter the
required followed
by the
button. The data of the new location will now be displayed (e.g.
34
followed
by the
button will automatically step you to the beginning of the Subscriber ID Number
for Receiver 1).
To move to the next location, press the
button. This will step you to the next location
and the data in that location will be displayed (e.g. If you are currently positioned at
“LOCATION 034”, pressing the
button will step you to “LOCATION 035”).
If you press the
button without previously entering a location number, the system will
step back one location (e.g. If you are positioned at “LOCATION 035” and you press the
button, you will step back one location to LOCATION 034).
Electronics Design and Manufacturing Pty Limited
ISSUE130
Summary of Contents for Solution 862
Page 1: ...Solution 862 Installation Manual ISSUE 1 30...
Page 2: ......
Page 4: ......
Page 6: ......
Page 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 245: ...Programming Sheets...
Page 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 255: ...Index...
Page 262: ......