156
Solution 862
Installation Manual
Day Alarm Zones
LOCATION 265
0
When programming this location, you will notice that there are four options per location. You
may select one, two, three or all four of these options, however, only one number needs to be
programmed. This number is calculated by adding the option bit numbers together. Program a
seven (7) if you require options 1, 2 and 4 simultaneously (i.e. 1 + 2 + 4 = 7).
Option
Day Alarm Zone
1
Zone 1
2
Zone 2
4
Zone 3
8
Zone 4
Table 69: Day Alarm Zones 1 - 4
Day alarm allows a combination of zones to be monitored while the system is in the disarmed
state. Indications are available via any of the programmable outputs including the codepad
buzzer. This function has been expanded to accommodate latching and non-latching day alarm
output event types.
When the system has been armed in AWAY Mode, STAY Mode 1 or STAY Mode 2, zones
that have been programmed as day alarm zones will activate the sirens and dialler just as non
day alarm zones do. When day alarm has been activated, it will ignore any zone pulse count
settings that have been programmed for that zone (i.e. Zone pulse count is only relevant when
the system has been armed).
Example
An example of day alarm set up could be the front door of a shop which has a pressure mat or
electronic beam that customers activate as they enter to and from the shop. As the customers
walk on the pressure mat or break the electronic beam, the codepad buzzer will beep.
Day Alarm Resetting
An output that has been programmed for day alarm resetting will operate when a zone
programmed for day alarm has been triggered. The output will reset once the zone has
resealed. This will only occur when the system is disarmed. Refer to Output Event Type Day
Alarm Resetting on page 193 for more information.
Day Alarm Latching
An output that has been programmed for day alarm latching will operate when a zone
programmed for day alarm has been triggered. The
ZONE
indicator and the latching output
will reset when the
button has been pressed. This will only occur when the system is
disarmed. Refer to Output Event Type - Day Alarm Latching on page 193 for more
information.
ISSUE130
Electronics Design and Manufacturing Pty Limited
Summary of Contents for Solution 862
Page 1: ...Solution 862 Installation Manual ISSUE 1 30...
Page 2: ......
Page 4: ......
Page 6: ......
Page 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 245: ...Programming Sheets...
Page 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 255: ...Index...
Page 262: ......