![EDM Solution 862 Installation Manual Download Page 217](http://html1.mh-extra.com/html/edm/solution-862/solution-862_installation-manual_2362278217.webp)
System and Consumer Options
217
System Options 3
LOCATION 426
8
Option
Description
1
AC Fail After 1 Hour (Disabled = After 2 Minutes)
2
Ignore AC Mains Fail Indication
4
Pulse Count Handover
8
Handover Delay To Be Sequential
1
2
4
Table 127: System Options 3
AC Fail After 1 Hour (Disabled = After 2 Minutes)
If this option has been selected, the
MAINS
indicator will begin to flash as soon as the AC
mains supply becomes disconnected. An "AC Loss" signal (Contact ID Event Code 301) will
be transmitted to the base station receiver after the AC mains supply has been disconnected
continuously for more than 60 minutes.
If this option has not been selected, the
MAINS
indicator will begin to flash and an "AC Loss"
signal (Contact ID Event Code 301) will be transmitted to the base station receiver after the
AC mains power has been disconnected continuously for 2 minutes.
The
MAINS
indicator will cease to flash once the AC mains supply has been restored for more
than two minutes.
An “AC Loss Restore” report will be transmitted to the base station receiver after the AC
mains supply has been restored continuously for more than 2 minutes irrespective of this
option being set.
Ignore AC Fail
If this option has been selected, the
MAINS
indicator will not flash, nor will the codepad beep
once every minute when the AC mains has been disconnected from the control panel. If you
require a programmable output to operate when the AC mains has failed, refer to Output Event
Type – AC Fail on page 194.
If this option has been selected, an “AC Loss” report (Contact ID Event Code 301) will still
report to the base station receiver unless disabled in “LOCATION 348 - 349” on page 183.
Zone Pulse Count Handover
If this option has been selected, any zone pulse count readings will handover and accumulate to
any zone that is triggered during the same arming cycle. Zone pulse count handover will only
operate with zone pulse count options 8-15. Refer to Zone Pulse Count on page 165 and Zone
Pulse Count Time on page 166 for more information.
24-hour zones do not receive any handover pulses from other zones. 24-hour zones can
handover pulses to other zones.
Handover Delay To Be Sequential
8
If this option has been selected, handover delay will be sequential (i.e. In numerical order from
lowest to highest). If the sequence is broken before the entry time expires, an alarm will occur.
If this option has not been selected, handover delay will follow the entry path provided that a
delay zone has been triggered first. Refer to Handover Zone on page 162 for more
information.
Electronics Design and Manufacturing Pty Limited
ISSUE130
Summary of Contents for Solution 862
Page 1: ...Solution 862 Installation Manual ISSUE 1 30...
Page 2: ......
Page 4: ......
Page 6: ......
Page 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 245: ...Programming Sheets...
Page 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 255: ...Index...
Page 262: ......