![EDM Solution 862 Installation Manual Download Page 253](http://html1.mh-extra.com/html/edm/solution-862/solution-862_installation-manual_2362278253.webp)
Location 424
Page 215
System Options 1
Location 425
Page 216
System Options 2
Location 426
Page 217
System Options 3
Location 427
Page 218
System Options 4
Location 428
Page 219
Consumer Options 1
Location 429
Page 220
Consumer Options 2
Location 430
Page 221
Consumer Options 3
Location 431
Page 222
Radio Input Options
Location 748 - 749
Page 142
Ring Burst Count
Location 900
Page 41
Disable Factory Default
Location 901 – 904
Page 210
System Time
Location 905 – 910
Page 211
System Date
1
1 = EDM Smart Lockout Allowed
2 = Horn Speaker Monitor
4 = Strobe Indications For Radio Arm/Disarm
8 = Horn Speaker Beeps For Radio Arm/Disarm
1 = Codepad Panic To Be Silent
2 = Codepad Fire To Be Silent
4 = Codepad Medical To Be Silent
8 = Access Denied To Be Silent
0
1 = AC Fail After 1 Hour (Disabled = After 2 Minutes)
2 = Ignore AC Fail
4 = Pulse Count Handover Allowed
8 = Handover Delay To Be Sequential
8
0
1 = Panel To Power Up In The Disarmed (If Power Reset)
2 = Arm/Disarm Tracking On Power Up
4 = Internal Crystal To Keep Time
8 = Keyswitch Interface, Night Arm Station Or RE005 Installed
1 = Test Reports Only When Armed
2 = Test Report After Siren Reset
4 = Auto Arm In STAY Mode 1
8 = STAY Indicator To Display Day Alarm Status
0
1 = Codepad Display Extinguish After 60 Seconds
2 = Single Button Arming In Allowed (AWAY/STAY Mode 1 & 2)
4 = Single Button Disarming Allowed (STAY Mode 1 & 2)
8 = Alarm Memory Reset On Disarm
2
5
1 = Codepad Fault Alarm Beeps Allowed
2 = Use Digit 3 For Codepad Duress Instead Of Digit 9
4 = Alarms Activate Siren & Strobe Outputs In STAY Mode 1 & 2
8 = Reserved
1 = Radio Receiver (WE800)
2 = Latching Keyswitch Input
3 = Momentary Keyswitch Input
4 = Reserved
0
4 6
Location 748
Increments Of 5 ms
Location 749
Increments Of 80 ms
0 = Defaulting Enabled
15 = Defaulting Disabled
0
Location 901
Hour Of The Day (Tens Digit)
Location 902
Hour Of The Day (Units Digit)
Location 903
Minute Of The Day (Tens Digit)
Location 904
Minute Of The Day (Units Digit)
0 0 0 0
0 1 0 1 0 1
Location 905
Day Of The Month (Tens Digit)
Location 906
Day Of The Month (Units Digit)
Location 907
Month Of The Year (Tens Digit)
Location 908
Month Of The Year (Units Digit)
Location 909
Year (Tens Digit)
Location 910
Year (Units Digit)
Solution 862
Programming Sheets
253
Electronics Design and Manufacturing Pty Limited
ISSUE130
Summary of Contents for Solution 862
Page 1: ...Solution 862 Installation Manual ISSUE 1 30...
Page 2: ......
Page 4: ......
Page 6: ......
Page 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 245: ...Programming Sheets...
Page 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 255: ...Index...
Page 262: ......