Optional Equipment
227
2 Wire Smoke Detector Interface (FA101)
The 2 Wire Smoke Detector Interface (FA101) has been designed to allow high quality 2 wire,
24 volt DC smoke detectors to be easily connected to the Solution range of control panels. The
interface provides the 24 volts required to power the smoke detector and also provides a relay
output that is used to trigger the control panel. Multiple detectors may be connected to the
same interface.
Radio Key/Keyswitch Interface (CC813)
This interface was designed to allow simple interfacing of a momentary keyswitch or radio
equipment for remote control operations to operate the control panel.
If the R/K terminal is used, a number of momentary keyswitches may be connected in parallel
for multiple arm/disarm locations. The ON and OFF terminals can be used to directly interface
to any access control system.
The HOME terminal will force the system to arm and disarm in STAY Mode 1.
There is also a PANIC terminal that allows the customer to issue a panic alarm from a remote
keyswitch or hand held radio transmitter.
This is handy if you require your system to be radio controlled and you would like to give your
customer total control via a hand held radio remote.
Electronics Design and Manufacturing Pty Limited
ISSUE130
Summary of Contents for Solution 862
Page 1: ...Solution 862 Installation Manual ISSUE 1 30...
Page 2: ......
Page 4: ......
Page 6: ......
Page 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 245: ...Programming Sheets...
Page 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 255: ...Index...
Page 262: ......