Alarm Link Operations
117
Alarm Link Options
LOCATION 180
3
Option
Description
1
Enable Upload/Download Via Alarm Link
2
Enable Alarm Link Call Back
4
Terminate Alarm Link Connection On Alarm
8
Use External Modem Module (CC811) For Alarm Link Operations
1
2
4
8
Table 44: Alarm Link Options
Enable Upload/Download Via Alarm Link
This option will need to be selected if you require to use the Alarm Link Software (CC816) to
remotely program the control panel. The control panel will not respond to the Alarm Link
Software if this option is not selected. Refer to Alarm Link Software on page 114 for more
information.
Enable Alarm Link Call Back
If this option has been selected and a call back telephone number has been programmed, the
remote programming computer must be connected to the telephone line that has been
programmed in the call back telephone number in “LOCATION 159 - 174” on page 139.
If this option is not selected, it will allow the installer to connect to their customers control
panel from any remote location when attempting upload/download operations without the need
to wait for the control panel to call back to the remote computer, but still allows the ability for
the customer to initiate the modem call from the codepad when requested by holding down the
6
button. Refer to Alarm Link Software on page 114 for more information.
Terminate Alarm Link Connection On Alarm
If the control panel is communicating with a remote computer via Alarm Link Software
(CC816) and an alarm has registered, the Alarm Link session will be terminated and the
relevant alarm message will then be transmitted to the base station receiver.
If an alarm occurs that does not need to report to the base station receiver, the session will not
be terminated. If this option has not been selected and an alarm has registered, the Alarm Link
software will prompt the operator with a “Terminate” or “Continue” message.
Use External Modem Module (CC811) For Alarm Link Operations
If this option has been selected, the control panel will use the external plug-in Module (CC811)
for remote programming operations via the Alarm Link Software (CC816). This option should
only be enabled where the telephone line is susceptible to noise.
Electronics Design and Manufacturing Pty Limited
ISSUE130
Summary of Contents for Solution 862
Page 1: ...Solution 862 Installation Manual ISSUE 1 30...
Page 2: ......
Page 4: ......
Page 6: ......
Page 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 245: ...Programming Sheets...
Page 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 255: ...Index...
Page 262: ......