10
Day Alarm Enabled
This output will operate as soon as day alarm has been enabled. The output will
reset when day alarm has been turned off. Refer to Day Alarm Zones on page 156
for programming zones to operate for day alarm.
Day alarm can be turned on and off by holding down the
4
button. Three beeps
indicates that day alarm has been turned on, two beeps indicates that day alarm has
been turned off. Refer to Hold Down Functions on page 107 for further information
on day alarm.
11
Telephone Line Fail
This output will operate when the in-built telephone line fault module detects that
the telephone line has been disconnected for a period of approximately 40 seconds.
The output will reset once the telephone line has been restored continuously for
more than 40 seconds. This output will not operate unless Option 1 in “LOCATION
176” on page 141 has been enabled.
12
Kiss-Off Received
This output will operate after the control panel has successfully transmitted to the
receiving party.
13
Fuse Fail
This output will operate when either the 1 Amp codepad fuse or the 1 Amp
accessories fuse fails. The output will reset once the faulty fuse has been replaced.
14
AC Fail
This output will operate as soon as the AC mains has failed. The output will reset as
soon as the AC mains has restored. This output will operate regardless of Option 2
in "LOCATION 426" on page 217 being set.
15
Low Battery
This output will operate when a dynamic battery test detects that the battery has
failed or the battery voltage has fallen below 10.5 volts. The dynamic battery test is
performed every four hours from when the system has been powered up or every
time the system has been armed in AWAY Mode, STAY Mode 1 or STAY Mode 2.
This output will reset only after a dynamic battery test reports the backup battery has
restored.
16
Horn Speaker Monitor Fail
If Option 2 – Enable Monitoring Of Horn Speaker in "LOCATION 424" on page
215 has been selected, this output will operate when the horn speaker has been
disconnected. The output will reset when the horn speaker has been reconnected.
17
Sensor Watch Alarm
This output will operate when the sensor watch count has been reached. Refer to
Zone Options 1 on page 167 for more information on programming zones for sensor
watch. Refer to "LOCATION 408 - 409" on page 206 for setting how many days
before a zone can register as a faulty sensor watch zone.
18
Codepad Medical Alarm
This output will operate when a codepad medical alarm has been activated by
pressing the
7
and
9
buttons simultaneously on the remote codepad. This output
will reset once a valid user code has been entered at the remote codepad.
ISSUE130
Electronics Design and Manufacturing Pty Limited
Summary of Contents for Solution 862
Page 1: ...Solution 862 Installation Manual ISSUE 1 30...
Page 2: ......
Page 4: ......
Page 6: ......
Page 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 245: ...Programming Sheets...
Page 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 255: ...Index...
Page 262: ......