Codepad Fire Alarm
This output will operate when a codepad medical alarm has been activated by
pressing the
4
and
6
buttons on the remote codepad simultaneously. This output
will reset once a valid user code has been entered at the remote codepad.
1
Codepad Panic Alarm
This output will operate when a codepad panic alarm (audible or silent) has been
activated by pressing the
1
and
3
buttons or the
and
buttons on the
remote codepad simultaneously. This output will reset once a valid user code has
been entered at the remote codepad.
1
Codepad Duress Alarm
This output will operate when a duress alarm has been activated by adding a
9
to
the end of the user code being used to disarm the system. his output will reset the
next time the system has been armed.
1
Codepad Tamper – Access Denied
This output will operate when the wrong code has been entered more times than
allowed. Refer to "LOCATION 356" on page 185 for setting the number of
incorrect attempts that may be allowed. This output will reset once a valid user code
has been entered.
1
Horn Speaker (Output 1 Only)
This output will operate only on Output 1 and should be programmed whenever an 8
ohm horn speaker is required. maximum of two horn speakers may be used.
Refer to “LOCATION 411” on page 207 for setting the siren run time and
“LOCATION 412” on page 207 for setting the siren sound rate.
If you require monitoring of the horn speaker, refer to Option 2 in “LOCATION
424” on page 215.
1
Sirens Running
This output will operate for the duration of the siren run time programmed in
"LOCATION 411" on page 207.
en the sirens have been activated, this output
will reset once the siren run time has expired. The relay output (Output 4) is factory
default for this operation.
20
Strobe Operating
This output will operate when an alarm condition occurs and will reset once a valid
user code has been entered. he strobe output (Output 3) is factory default for
strobe operation and is programmed to automatically reset after 8 hours.
21
Silent Alarm
This output will operate when any zone programmed to be a silent alarm has
triggered. The output will reset when the siren run time expires, an audible alarm
has triggered, or a valid user code has been entered.
22
Alarm When In STAY Mode
This output will operate whenever an audible or silent zone alarm has triggered
when the system has been armed in STAY Mode 1 or STAY Mode 2. he output
will reset when the system has been disarmed.
Programmable Outputs
195
Electronics Design and Manufacturing Pty Limited
ISSUE130
T
A
Wh
T
T
Summary of Contents for Solution 862
Page 1: ...Solution 862 Installation Manual ISSUE 1 30...
Page 2: ......
Page 4: ......
Page 6: ......
Page 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 245: ...Programming Sheets...
Page 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 255: ...Index...
Page 262: ......